Tomographic reconstruction for tilted helical multislice CT.

Abstract

One of the most recent technical advancements in computed tomography (CT) is the introduction of multislice CT (MCT). Because multiple detector rows are used for data acquisition, MCT offers higher volume coverage, faster scan speed, and reduced X-ray tube loading. Recognizing its unique data-sampling pattern, several image reconstruction algorithms were developed. These algorithms have been shown to be adequate in producing clinically acceptable images. Recent studies, however, have revealed that the image quality of MCT can be significantly degraded when helical data are acquired with a tilted gantry. The degraded image quality has rendered this feature unacceptable for clinical usage. In this paper, we first present a detailed investigation on the cause of the image quality degradation. An analytical model is derived to provide a mathematical basis for correction. Several compensation schemes are subsequently presented, and a detailed performance comparison is provided in terms of spatial resolution, noise, computation efficiency, and image artifacts.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Hsieh. 2000. Tomographic reconstruction for tilted helical multislice CT.. https://doi.org/10.1109/42.887835

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multidetector CT and dentascan software: dosimetric evaluation and technique improvement.

PURPOSE: The development of new operative techniques in oral and maxillofacial surgery within the last few years has led to an increasing demand for Dentascan examination, also in paediatric patients. It is necessary to modify acquisition parameters to reduce the absorbed dose. The aim of this study was to define a Dentascan protocol in which a reduced X-ray dose could be used. MATERIALS AND METHODS: Dosimeters were applied to the eyes, mouth, parotid glands, thyroid and back of the neck of an anthropomorphic Plexiglas phantom that underwent multidetector computed tomography (MDCT) Dentascan examinations. Both 120kV and 80 kV were used to study the mandibular and maxillary arches. RESULTS: Examinations obtained with the 80 kV protocol showed a ten-fold reduction in the absorbed dose, without affecting image quality. CONCLUSIONS: We suggest a Dentascan protocol that reduces the X-ray dose administered to the patient while ensuring the same high diagnostic accuracy.

Head↗