PubMed Health⌕ Search

PubMed · 11127608

Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.

Abstract

Preliminary evaluation of recently developed large-area flat panel detectors (FPDs) indicates that FPDs have some potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high detective quantum efficiency (DQE), high frame rate and high dynamic range, small image lag (< 1%), and excellent linearity (approximately 1%). The advantages of the new FPD make it a promising candidate for cone-beam volume computed tomography (CT) angiography (CBVCTA) imaging. The purpose of this study is to characterize a prototype FPD-based imaging system for CBVCTA applications. A prototype FPD-based CBVCTA imaging system has been designed and constructed around a modified GE 8800 CT scanner. This system is evaluated for a CBVCTA imaging task in the head and neck using four phantoms and a frozen rat. The system is first characterized in terms of linearity and dynamic range of the detector. Then, the optimal selection of kVps for CBVCTA is determined and the effect of image lag and scatter on the image quality of the CBVCTA system is evaluated. Next, low-contrast resolution and high-contrast spatial resolution are measured. Finally, the example reconstruction images of a frozen rat are presented. The results indicate that the FPD-based CBVCT can achieve 2.75-lp/mm spatial resolution at 0% modulation transfer function (MTF) and provide more than enough low-contrast resolution for intravenous CBVCTA imaging in the head and neck with clinically acceptable entrance exposure level. The results also suggest that to use an FPD for large cone-angle applications, such as body angiography, further investigations are required.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Ning, B Chen, R Yu, D Conover, X Tang, Y Ning. 2000. Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.. https://doi.org/10.1109/42.887842

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.

Angiography↗