Cone beam volume CT image artifacts caused by defective cells in x-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm.

The application of x-ray flat panel imagers (FPIs) in cone beam volume CT (CBVCT) has attracted increasing attention. However, due to a deficient semiconductor array manufacturing process, defective cells unavoidably exist in x-ray FPIs. These defective cells cause their corresponding image pixels in a projection image to behave abnormally in signal gray level, and result in severe streak and ring artifacts in a CBVCT image reconstructed from the projection images. Since a three-dimensional (3-D) back-projection is involved in CBVCT, the formation of the streak and ring artifacts is different from that in the two-dimensional (2-D) fan beam CT. In this paper, a geometric analysis of the abnormality propagation in the 3D back-projection is presented, and the morphology of the streak and ring artifacts caused by the abnormality propagation is investigated through both computer simulation and phantom studies. In order to calibrate those artifacts, a 2D wavelet-analysis-based statistical approach to correct the abnormal pixels is proposed. The approach consists of three steps: (1) the location-invariant defective cells in an x-ray FPI are recognized by applying 2-D wavelet analysis on flat-field images, and a comprehensive defective cell template is acquired; (2) based upon the template, the abnormal signal gray level of the projection image pixels corresponding to the location-invariant defective cells is replaced with the interpolation of that of their normal neighbor pixels; (3) that corresponding to the isolated location-variant defective cells are corrected using a narrow-windowed median filter. The CBVCT images of a CT low-contrast phantom are employed to evaluate this proposed approach, showing that the streak and ring artifacts can be reliably eliminated. The novelty and merit of the approach are the incorporation of the wavelet analysis whose intrinsic multi-resolution analysis and localizability make the recognition algorithm robust under variable x-ray exposure levels between 30% and 70% of the dynamic range of an x-ray FPI.

Algorithms↗

A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit.

The circle-plus-arc orbit possesses advantages over other "circle-plus" orbits for the application of x-ray cone beam (CB) volume CT in image-guided interventional procedures requiring intraoperative imaging, in which movement of the patient table is to be avoided. A CB circle-plus-two-arc orbit satisfying the data sufficiency condition and a filtered backprojection (FBP) algorithm to reconstruct longitudinally unbounded objects is presented here. In the circle suborbit, the algorithm employs Feldkamp's formula and another FBP implementation. In the arc suborbits, an FBP solution is obtained originating from Grangeat's formula, and the reconstruction computation is significantly reduced using a window function to exclude redundancy in Radon domain. The performance of the algorithm has been thoroughly evaluated through computer-simulated phantoms and preliminarily evaluated through experimental data, revealing that the algorithm can regionally reconstruct longitudinally unbounded objects exactly and efficiently, is insensitive to the variation of the angle sampling interval along the arc suborbits, and is robust over practical x-ray quantum noise. The algorithm's merits include: only 1D filtering is implemented even in a 3D reconstruction, only separable 2D interpolation is required to accomplish the CB backprojection, and the algorithm structure is appropriate for parallel computation.

Algorithms↗

MR volumetric analysis of the human basal ganglia: normative data.

RATIONALE AND OBJECTIVES: The authors undertook this study to identify a precise, semiautomated, reproducible magnetic resonance (MR) imaging technique for measuring the basal ganglia, to establish normative volumetric data, and to verify the presence of previously reported asymmetries. MATERIALS AND METHODS: Twenty-eight healthy adults underwent cranial MR examination. The volumes of the various components of the basal ganglia were measured by means of a combination of thresholding and manual tracing techniques performed with specialized software. The validity of these measurements was assessed by fashioning, imaging, and measuring a practical basal ganglia phantom. Measurement accuracy was also established by means of inter- and intrarater reliability indexes. Normalized volumes were statistically analyzed with analysis of variance and paired t tests. RESULTS: The absolute values of the various components of the basal ganglia varied widely even though the volumes were normalized to differences in intracranial volume. The right caudate nucleus volume was significantly (P < .000001) larger than the left in both men and women and in both right-handed and non-right-handed subjects. This asymmetry led to an increase in the overall volume of the basal ganglia on the right. CONCLUSION: The authors have defined a precise, reproducible technique for measuring various components of the basal ganglia and have established normative data. The basal ganglia, similar to other brain structures, exhibit hemispheric lateralization.

Adult↗

Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.

Preliminary evaluation of recently developed large-area flat panel detectors (FPDs) indicates that FPDs have some potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high detective quantum efficiency (DQE), high frame rate and high dynamic range, small image lag (< 1%), and excellent linearity (approximately 1%). The advantages of the new FPD make it a promising candidate for cone-beam volume computed tomography (CT) angiography (CBVCTA) imaging. The purpose of this study is to characterize a prototype FPD-based imaging system for CBVCTA applications. A prototype FPD-based CBVCTA imaging system has been designed and constructed around a modified GE 8800 CT scanner. This system is evaluated for a CBVCTA imaging task in the head and neck using four phantoms and a frozen rat. The system is first characterized in terms of linearity and dynamic range of the detector. Then, the optimal selection of kVps for CBVCTA is determined and the effect of image lag and scatter on the image quality of the CBVCTA system is evaluated. Next, low-contrast resolution and high-contrast spatial resolution are measured. Finally, the example reconstruction images of a frozen rat are presented. The results indicate that the FPD-based CBVCT can achieve 2.75-lp/mm spatial resolution at 0% modulation transfer function (MTF) and provide more than enough low-contrast resolution for intravenous CBVCTA imaging in the head and neck with clinically acceptable entrance exposure level. The results also suggest that to use an FPD for large cone-angle applications, such as body angiography, further investigations are required.

Angiography↗

A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry.

In cone-beam computerized tomography (CT), projections acquired with the focal spot constrained on a planar orbit cannot provide a complete set of data to reconstruct the object function exactly. There are severe distortions in the reconstructed noncentral transverse planes when the cone angle is large. In this work, a new method is proposed which can obtain a complete set of data by acquiring cone-beam projections along a circle-plus-arc orbit. A reconstruction algorithm using this circle-plus-arc orbit is developed, based on the Radon transform and Grangeat's formula. This algorithm first transforms the cone-beam projection data of an object to the first derivative of the three-dimensional (3-D) Radon transform, using Grangeat's formula, and then reconstructs the object using the inverse Radon transform. In order to reduce interpolation errors, new rebinning equations have been derived accurately, which allows one-dimensional (1-D) interpolation to be used in the rebinning process instead of 3-D interpolation. A noise-free Defrise phantom and a Poisson noise-added Shepp-Logan phantom were simulated and reconstructed for algorithm validation. The results from the computer simulation indicate that the new cone-beam data-acquisition scheme can provide a complete set of projection data and the image reconstruction algorithm can achieve exact reconstruction. Potentially, the algorithm can be applied in practice for both a standard CT gantry-based volume tomographic imaging system and a C-arm-based cone-beam tomographic imaging system, with little mechanical modification required.

Algorithms↗

Image intensifier-based computed tomography volume scanner for angiography.

RATIONALE AND OBJECTIVES: A prototype volume computed tomography (CT) system for use in angiography was designed, constructed, and tested. The system consisted of a fixed X-ray tube, a conventional image intensifier (II) coupled to a charge-coupled device camera, and a computer-controlled turntable on which phantoms were placed. We wanted to predict, through phantom studies, the imaging performance of an II-based volume CT for direct three-dimensional (3D) reconstruction of vascular structures. METHODS: To explore the imaging performance of the system for reconstructing a vascular structure, two sets of projection images of a vascular phantom, acquired over 250 projection angles with two different-sized IIs, were digitized and used for a direct 3D conebeam reconstruction. The signal-to-noise ratio (SNR) of each reconstructed image was measured. From these measurements, image quality was accessed as a function of the number of reconstructions averaged and the different orientations. The spatial resolution limits of the system were measured from the 3D reconstructed images of a specially designed resolution phantom for different orientations and locations. RESULTS: The measured SNRs of all direct 3D reconstruction images were reasonably good, and back-ground noise levels measured from 3D reconstruction images were almost 30 Hounsfield units. The measured spatial resolution of the system was 0.5 line pairs per millimeter. However, spatial resolution was reduced around the edge of the II to nearly half that measured in the central area of the field of view. CONCLUSION: An II-based volume CT scanner can produce direct 3D reconstructions of vascular structures with good image quality for intraarterial angiography.

Angiography↗

Radioimmunoassay of the anticonvulsant agent clonazepam.

A simple and specific radioimmunoassay was developed for the determination of the anticonvulsant agent clonazepam directly in plasma without extraction. Antibodies to clonazepam were produced in rabbits after immunization with an immunogen prepared by covalently linking the 3-hemisuccinyloxy derivative of clonazepam to bovine serum albumin. When employing 3H-clonazepam as the tracer, the radioimmunoassay has a limit of sensitivity of 5 ng/ml using a 0.1-ml sample of plasma. The antibodies exhibited a high degree of specificity for clonazepam; no cross-reactivity was observed with its 7-amino and 7-acetylamino metabolites nor with a number of other widely prescribed anticonvulsant agents that might be administered in conjuction with clonazepam. Satisfactory agreement was obtained for the plasma levels of clonazepam in humans when samples were assayed by the radioimmunoassay and an established electron-capture GC technique. By virtue ot its simplicity, the radioimmunoassay offers a distinct advantage to the clinician for monitoring plasma clonazepam levels and the compliance of patients undergoing anticonvulsant therapy with the drug.

Animals↗

Reconstruction of blood vessels from x-ray subtraction projections: limited angle geometry.

Several algorithms have been investigated for reconstructing blood vessels from a limited number of x-ray subtraction projections, distributed over a limited range of angles. Both computer simulations and an in vivo animal study were carried out. The best reconstruction performance was achieved using an algorithm that folded in two pieces of a priori knowledge of the vascular density distributions: (1) the object is dilute, consisting mainly of a void; and (2) the density distribution in the reconstructions is most likely to be non-negative. Both the signal-to-noise ratio (SNR) and the signal to out-of-focus blur were quantitated. Compared to tomosynthetic reconstruction (backprojection), the amount of residual blur from out-of-focus planes was significantly reduced with only a small penalty in diminished SNR. The combined effect resulted in significant qualitative image improvement for real arterial distributions as demonstrated in a canine arterial imaging example.

Algorithms↗

Computer simulation of image intensifier-based computed tomography detector: vascular application.

This present study reports the results of a computer simulation whose aim was to predict the low-contrast imaging performance of which a conventional x-ray image intensifier with charge coupled device (CCD) camera would be capable if incorporated into a computed tomography (CT) volume imager. A vascular imaging task was modeled in our simulation. The effects of detector noise, x-ray exposure levels, analog-to-digital conversion (ADC) precision and residual levels of detected x-ray scatter were considered. The results of this simulation indicate that the low-contrast imaging performance of an image intensifier-based CT system was most limited by the CCD detector readout noise. Given this limitation the detection of greater than about 100,000 detected photons/pixel/projection gave marginal improvement in low-contrast resolution. At these exposures 12 bit ADC precision resulted in little additional image noise. The effects of detecting scattered x rays are twofold; decreasing the signal-to-noise ratio associated with our modeled artery and introducing a cupping artifact. Based on the results from the simulation, it appears that an image intensifier-based CT system is a feasible concept from a noise viewpoint, if the anticipated imaging task is intravenous angiography.

Angiography↗