Changes in AV node conduction curves following slow pathway modification.

Abstract

Dual AV node physiology often persists after successful slow pathway (SP) ablation, and the mechanism of tachycardia elimination is unresolved. Therefore, AV node conduction curves were analyzed following successful ablation (4 +/- 1 energy applications) in 85 consecutive patients (58 women, age 50 +/- 2 years) with typical AVNRT. Twenty-seven patients (32%) had complete elimination (group 1) whereas 58 (68%) patients had persistence (group 2) of dual AV node physiology. A significant increase in the AV node Wenckebach cycle length (WB-CL) was observed in both groups (310 +/- 9 to 351 +/- 15 ms in group 1, and 325 +/- 8 to 369 +/- 9 ms in group 2, P < 0.05). A decrease in the fast pathway (FP) ERP (339 +/- 15 to 279 +/- 12 ms) and an increase in the maximum FP AH interval (141 +/- 5 to 171 +/- 7) were observed only in group 1 (P < 0.05). In group 2, no change in the SP ERP (267 +/- 7 to 280 +/- 10 ms) was observed, and the change in the maximum SP-AH following ablation showed a significant inverse relation to the maximum SP-AH at baseline in group 2. In conclusion, (1) an increase in the WB-CL is observed independent of the persistence or elimination of dual physiology after successful ablation; (2) when dual physiology is eliminated, significant changes in the FP ERP and the maximum FP-AH occur; (3) when dual physiology persists, FP physiology and the SP ERP remain unchanged, and a significant inverse relation between the change in the maximum SP-AH following ablation and the maximum baseline SP-AH is observed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Geller, A Goette, S Reek, C Funke, W M Hartung, H U Klein. 2000. Changes in AV node conduction curves following slow pathway modification.. https://doi.org/10.1046/j.1460-9592.2000.01651.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biventricular repair of right-dominant complete atrioventricular canal defect.

Complete atrioventricular (AV) canal defects usually have right and left valve components of approximately equal size, although unbalanced forms do occur. Optimal management of unbalanced AV canal defects is controversial, with no proven guidelines for choosing between biventricular repair and univentricular palliation. We describe successful biventricular repair of a right-dominant unbalanced AV canal with severe left AV valve stenosis. This case illustrates that severely unbalanced AV canal defects can be repaired successfully by tailoring the AV valve to distribute it equally between the ventricles, The increase in left ventricular volume after surgery exceeded prediction based on conformational change alone.

Atrioventricular Node↗

Junctional rhythm in hypertrophic cardiomyopathy: a case report.

We observed a case of a 47-year-old male patient with hypertrophic cardiomyopathy and family history of sudden death. During cardiac catheterization, the patient presented spontaneous intermittent atrioventricular junctional rhythm without significant changes related to sinus heart rate. The gradient was absent with sinus beats, but the junctional rhythm induced the appearance of a left ventricular-aorta gradient, with parallel reduction of aortic pressure from 156 to 120 mm Hg. Subsequently, a couple of pre-mature ventricular beats induced an important post-extrasystolic potentiation of the gradient, followed in the last beats by sinus rhythm with disappearance of the gradient. Our case suggests that the decrease of left ventricular volume, due to the absence of an effective atrial systole, leads to left ventricular increased gradient, not imputable to an increased inotropic effect or heart rate modifications but to the decrease of pre-load.

Atrioventricular Node↗