Abstract

PURPOSE: The increasing complexity of radiotherapy highlights the need for accurate setup. This paper assesses the potential of position corrections, derived from the three-dimensional (3D) surface of the patient, in reducing positioning errors in patients undergoing conformal radiation therapy of the prostate. METHODS AND MATERIALS: Twenty patients undergoing conformal radiation therapy for prostate cancer had planning computed tomography (CT) scans and then weekly treatment CT scans over the course of their treatment. Patients were positioned on the CT table using three coplanar tattoo marks used for patient setup on the accelerator. Surfaces were computed from the planning CT (planning surface), and the treatment CT (treatment surfaces). Using a surface matching utility, the planning and treatment 3D surfaces were compared. The prostate was implicitly localized based on surface matching of the external contour and by matching the bony anatomy. The resultant prostate displacement after correction was assessed for the two localization methods. RESULTS: Correcting patient position via the surface comparisons reduced the standard deviation of prostate displacement with respect to the patient isocenter in the lateral and anterior/posterior directions. In the lateral direction, prostate and surface motion was highly correlated (r = 0.96). In the anterior/posterior direction the corrections from the surface data were as effective as those derived from the bony anatomy. CONCLUSION: Detailed surface data can aid the positioning of patients receiving conformal radiation therapy to the prostate by reducing the displacement of the target from the intended treatment position. This study shows that surface corrections can be as effective as those derived from bony anatomy, and may be exploited where definition of bony anatomy is difficult.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R I MacKay, P A Graham, J P Logue, C J Moore. 2001-01-01. Patient positioning using detailed three-dimensional surface data for patients undergoing conformal radiation therapy for carcinoma of the prostate: a feasibility study.. https://doi.org/10.1016/s0360-3016(00)01385-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A feasibility study on the use of visible and short wavelengths in the near-infrared region for the non-destructive measurement of wine composition.

The aim of this study was to explore the capability of spectroscopy in the visible (Vis) and short wavelength near-infrared (NIR) regions for the non-destructive measurement of wine composition in intact bottles. In this study we analysed a wide range of commercial wines obtained in Australia in different types of bottles (e.g. colours, diameters and heights), including different wine styles and varieties. Wine bottles were scanned in the Vis-NIR region (600-1,100 nm) in a monochromator instrument in transflectance mode. Principal component analysis (PCA) and partial least-squares (PLS) regression were used to interpret the spectra and develop calibrations for wine composition. Due to the relatively small number of samples available full cross-validation (leave-one-out) was used as validation. The coefficient of correlation in calibration [Formula: see text] and the standard error of cross-validation (SECV) were 0.67 (SECV: 0.48%), 0.83 (SECV: 4.01 mg L-1), 0.70 (SECV: 28.6 mg L-1) and 0.50 (SECV: 0.15) for alcohol content, total SO2, free SO2 and pH, respectively, in the set of wine samples analysed. These preliminary results showed that the assessment of wine composition by Vis and short wavelengths in the NIR is possible for either qualitative analysis (e.g. low-, medium- and high-quality grading), or for screening of composition during bottling and storage. Although low accuracy and precision were obtained for the chemical parameters routinely analysed in wine, calibration models for the chemical parameters were considered acceptable for screening purposes in terms of the standard errors obtained.

Feasibility Studies↗

Image-guided in vivo dosimetry for quality assurance of IMRT treatment for prostate cancer.

PURPOSE: In external beam radiotherapy (EBRT) and especially in intensity-modulated radiotherapy (IMRT), the accuracy of the dose distribution in the patient is of utmost importance. It was investigated whether image guided in vivo dosimetry in the rectum is a reliable method for online dose verification. METHODS AND MATERIALS: Twenty-one dose measurements were performed with an ionization chamber in the rectum of 7 patients undergoing IMRT for prostate cancer. The position of the probe was determined with cone beam computed tomography (CBCT). The point of measurement was determined relative to the isocenter and relative to an anatomic reference point. The dose deviations relative to the corresponding doses in the treatment plan were calculated. With an offline CT soft-tissue match, patient positioning after ultrasound was verified. RESULTS: The mean magnitude +/- standard deviation (SD) of patient positioning errors was 3.0 +/- 2.5 mm, 5.1 +/- 4.9 mm, and 4.3 +/- 2.4 mm in the left-right, anteroposterior and craniocaudal direction. The dose deviations in points at corresponding positions relative to the isocenter were -1.4 +/- 4.9% (mean +/- SD). The mean dose deviation at corresponding anatomic positions was 6.5 +/- 21.6%. In the rare event of insufficient patient positioning, dose deviations could be >30% because of the close proximity of the probe and the posterior dose gradient. CONCLUSIONS: Image-guided dosimetry in the rectum during IMRT of the prostate is a feasible and reliable direct method for dose verification when probe position is effectively controlled.