PubMed Health⌕ Search

PubMed · 11276739

Two-stage implant systems.

Abstract

Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of osseointegration. New types of reinforcements for dental implants and the use of growth factors to augment bone regeneration so that implants can be placed more easily are now being actively investigated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M E Fritz. 1999. Two-stage implant systems.. https://doi.org/10.1177/08959374990130010601

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A synergistic approach to the design, fabrication and evaluation of 3D printed micro and nano featured scaffolds for vascularized bone tissue repair.

3D bioprinting has begun to show great promise in advancing the development of functional tissue/organ replacements. However, to realize the true potential of 3D bioprinted tissues for clinical use requires the fabrication of an interconnected and effective vascular network. Solving this challenge is critical, as human tissue relies on an adequate network of blood vessels to transport oxygen, nutrients, other chemicals, biological factors and waste, in and out of the tissue. Here, we have successfully designed and printed a series of novel 3D bone scaffolds with both bone formation supporting structures and highly interconnected 3D microvascular mimicking channels, for efficient and enhanced osteogenic bone regeneration as well as vascular cell growth. Using a chemical functionalization process, we have conjugated our samples with nano hydroxyapatite (nHA), for the creation of novel micro and nano featured devices for vascularized bone growth. We evaluated our scaffolds with mechanical testing, hydrodynamic measurements and in vitro human mesenchymal stem cell (hMSC) adhesion (4 h), proliferation (1, 3 and 5 d) and osteogenic differentiation (1, 2 and 3 weeks). These tests confirmed bone-like physical properties and vascular-like flow profiles, as well as demonstrated enhanced hMSC adhesion, proliferation and osteogenic differentiation. Additional in vitro experiments with human umbilical vein endothelial cells also demonstrated improved vascular cell growth, migration and organization on micro-nano featured scaffolds.

Bone Regeneration↗

Transfer of apatite coating from porogens to scaffolds: uniform apatite coating within porous poly(DL-lactic-co-glycolic acid) scaffold in vitro.

Strategies to bone tissue engineering have focused on the use of synthetic or natural degradable materials as scaffolds for cell transplantation to guide bone regeneration. Biocompatibility, biodegradability, biomechanical integrity, and osteoconductivity are important requirements for the scaffold materials. This study explored a new approach of apatite coating to enhance the osteoconductivity of a synthetic degradable poly(DL-lactic-co-glycolic acid) (PLGA) scaffold. The new approach was developed to ensure a relatively uniform apatite coating on the interior pore surfaces deep inside a scaffold, even for a relatively thick scaffold with small pores. Apatite was first coated on the surface of paraffin spheres of the desirable sizes. The paraffin spheres were then molded to form a foam. PLGA/pyridine solution was cast into the interspaces among the paraffin spheres. After the paraffin spheres were dissolved and removed by cyclohexane, PLGA scaffold with controlled pore size, good interconnectivity and high porosity was obtained with apatite left on the pore surface uniformly throughout the whole scaffold. The scaffold and apatite coating were characterized using thermogravimetry analysis, scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffractometry.

Bone Regeneration↗

Electrospinning biomedical nanocomposite fibers of hydroxyapatite/poly(lactic acid) for bone regeneration.

Development of fibrous matrices of bioceramic-biopolymer nanocomposite offers great potential in the field of bone regeneration and tissue engineering. However, in order to produce electrospun fibers with homogeneous structure, it is essential for the ceramic powder to be fine and to remain stable in suspension. Herein, we developed a novel method whereby the bioceramic hydroxyapatite (HA) was kept in suspension in biopolymer poly(lactic acid) (PLA). The strategy was to introduce a surfactant hydroxysteric acid (HSA) between the hydrophilic HA powder and the hydrophobic chloroform-dissolved PLA. The HA nanopowder was dispersed effectively in HSA and mixed homogeneously with PLA. Continuous and uniform fibers were generated successfully with diameters of approximately 1-2 microm, and featured a well-developed nanocomposite structure of HA nanopowder-dispersed PLA. Initial cellular assays showed excellent cell attachment and proliferation and also enhanced expression of alkaline phosphatase at 7 days of culturing. The HA-PLA nanocomposite fibers may be potentially useful in tissue engineering applications, particularly as three-dimensional substrates for bone growth.

Bone Regeneration↗