PubMed Health⌕ Search

PubMed · 11409857

Maximizing effective audibility in hearing aid fitting.

Abstract

OBJECTIVE: This paper examines why more audibility is not always better than less audibility if hearing-impaired people are to best understand speech. DESIGN: We used speech perception data from 14 normally hearing and 40 hearing-impaired people to quantify the contribution of audibility to speech intelligibility. The quantification revealed that the effectiveness of audibility decreased with hearing loss, and the decrement was greater at high frequencies than at lower frequencies. To apply the Speech Intelligibility Index (SII) model to predict speech intelligibility for hearing-impaired people, we modified the model to take account of effective audibility rather than physical audibility. RESULTS: The modified SII model provided an adequate description of speech performance of people with a wide range of hearing threshold levels. We applied the model to the evaluation of two prescriptions for a sloping audiogram at prescribed levels and at equated loudness levels to demonstrate the necessity of considering loudness and effective audibility in prescribing amplification. Effective audibility is defined as audibility corrected for the effects of level distortion and hearing loss desensitization, and this paper proposes a method of estimating effective audibility from hearing threshold level at different frequencies. CONCLUSIONS: The practical implication of considering effective audibility in prescribing hearing aids is that for a given listening level, less gain is provided at frequencies where the hearing is most impaired to allow more gain at frequencies where audibility is most useful. In developing the NAL-NL1 prescription for nonlinear hearing aids, we adopted the modified SII model together with a loudness model to derive optimal gain-frequency response characteristics that maximize predicted speech intelligibility for people with different degrees of hearing losses.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Y Ching, H Dillon, R Katsch, D Byrne. 2001. Maximizing effective audibility in hearing aid fitting.. https://doi.org/10.1097/00003446-200106000-00005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cochlear implantation in obstructed cochleas: the effect of the degree of obstruction on the number of activated electrodes and the amount of postoperative speech perception.

OBJECTIVE: With cochlear implantation, insertion of the electrodes can be hampered by cochlear obstructions. The aim of this study was to investigate the effects of these obstructions on the number of activated electrodes and postoperative speech perception. STUDY DESIGN AND SETTING: Retrospective analysis of the operation reports and CT-scans of patients who underwent cochlear implantation, at the Department of Otorhinolaryngology of the University Medical Center of Utrecht (n = 295). PATIENTS AND INTERVENTIONS: Fifty patients with a certain degree of cochlear obstruction were included. Based on the surgical intervention to overcome these obstructions they were subdivided into first-, second- and third degree obstructions. The number of implanted and activated electrodes was determined. MAIN OUTCOME MEASURES: Three different speech perception tests after 12 months of cochlear implant use. RESULTS: The number of activated electrodes significantly diminished with increasing obstruction degree (P < 0.01). This was caused by a lower amount of implanted electrodes combined with a higher amount of switched off electrodes. With a higher degree of obstruction the amount of postoperative speech perception decreased significantly (P < 0.01). This is partly explained by the lower number of activated electrodes and partly explained by the fact that a higher obstructions degree correlates with a higher degree of (retro-) cochlear pathology. Significantly more electrodes can be inserted into the severely obstructed cochlea using a Double Array Cochlear Implant. CONCLUSION: Cochlear obstructions pose a surgical threat and negatively influence the postoperative speech perception results. Fortunately, due to surgical techniques, first and second degree obstructed cochleas can often be bypassed. Implanting of a Double Array implant brightens the prospects of patients with third (severe) degree obstructed cochleas.

Audiometry, Speech↗

Experimental comparison between speech transmission index, rapid speech transmission index, and speech intelligibility index.

During the acoustical design of, e.g., auditoria or open-plan offices, it is important to know how speech can be perceived in various parts of the room. Different objective methods have been developed to measure and predict speech intelligibility, and these have been extensively used in various spaces. In this study, two such methods were compared, the speech transmission index (STI) and the speech intelligibility index (SII). Also the simplification of the STI, the room acoustics speech transmission index (RASTI), was considered. These quantities are all based on determining an apparent speech-to-noise ratio on selected frequency bands and summing them using a specific weighting. For comparison, some data were needed on the possible differences of these methods resulting from the calculation scheme and also measuring equipment. Their prediction accuracy was also of interest. Measurements were made in a laboratory having adjustable noise level and absorption, and in a real auditorium. It was found that the measurement equipment, especially the selection of the loudspeaker, can greatly affect the accuracy of the results. The prediction accuracy of the RASTI was found acceptable, if the input values for the prediction are accurately known, even though the studied space was not ideally diffuse.

Audiometry, Speech↗