The reliability of pacemaker electrode-leads.

Abstract

Extensive experience has been obtained with Medtronic pacemakers, in Glasgow where over 400 patients have received their primary implant. In this review, which covers a period of seven and a half years ending December 31, 1973, the technical reliability of electrode-leads is considered in terms of failed implant lifetimes and incomplete implant lifetimes. Too few myocardial electrode-leads have been used to reach firm conclusions about its reliability, but the incidence of failures with the endocardial bipolar electrode-lead (Type 5818) has so far been small and it is evidently more reliable than its predecessor (Type 5816). More time must elapse, however, before it can be claimed with confidence that the present design of bipolar catheter will match the theoretical implant lifetimes of generators with the long-life power sources. Insulation failures are usually of no immediate clinical significance whereas any broken conductor is hazardous. The use of multistranded conductors is therefore advocated. All pacemakers should be retrieved after the deaths of patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G D Green. 1975. The reliability of pacemaker electrode-leads.. https://doi.org/10.1016/s0022-0736(75)80030-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The development of a multichannel electrode array for retinal prostheses.

The development of a multielectrode array is the key issue for retinal prostheses. We developed a 10 x 10 platinum electrode array that consists of an 8-microm polyimide layer sandwiched between 5-microm polymonochloro-para-xylylene (parylene-C) layers. Each electrode was formed as a 30-microm-high bump by Pt/Au double-layer electroplating. We estimated the charge delivery capability (CDC) of the electrode by measuring the CDCs of two-channel electrode arrays. The dimensions of each electrode of the two-channel array were the same as those of each electrode formed on the 10 x 10 array. The results suggest that for cathodic-first (CF) pulses, 80% of electrodes surpassed our development target of 318 microC/cm2, which corresponds to the charge density of pulses of 500 micros duration and 200 microA amplitude for a 200-microm-diameter planar electrode.

Electrodes, Implanted↗

Improved version of the printed circuit board (PCB) modular multi-channel microdrive for extracellular electrophysiological recordings.

The modular multi-channel PCB microdrive was described some years ago, since then several improvements were introduced while using these drives. Utilizing several years of experience with the original PCB microdrive we redesigned it to improve its stability and usability. The application of the printed circuit board technology and the extensive use of flexible fused silica capillaries for fabrication of the microdrive are described in detail. The improved design led to a low cost and light-weight multi-channel microdrive with outstanding modularity for extracellular field, single unit or multiunit tetrode recording up to 64/128 channels.

Electrodes, Implanted↗