Hydrophilic membrane-based humidity control.

Abstract

A dehumidification system for low gravity plant growth experiments requires the generation of no free-liquid condensate and the recovery of water for reuse. In the systems discussed in this paper, the membrane is a barrier between the humid air phase and a liquid-coolant water phase. The coolant water temperature combined with a transmembrane pressure differential establishes a water flux from the humid air into the coolant water. Building on the work of others, we directly compared different hydrophilic membranes for humidity control. In a direct comparison of the hydrophilic membranes, hollow fiber cellulose ester membranes were superior to metal and ceramic membranes in the categories of condensation flux per surface area, ease of start-up, and stability. However, cellulose ester membranes were inferior to metal membranes in one significant category, durability. Dehumidification systems using mixed cellulose ester membranes failed after operational times of only hours to days. We propose that the ratio of fluid surface area to membrane material area (approximately = membrane porosity) controls the relative performances among membranes. In addition, we clarified design equations for operational parameters such as the transmembrane pressure differential. This technology has several potential benefits related to earth environmental issues including the minimization of airborne pathogen release and higher energy efficiency in air conditioning equipment. Utilizing these study results, we designed, constructed, and flew on the space shuttle missions a membrane-based dehumidification system for a plant growth chamber.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Scovazzo, J Burgos, A Hoehn, P Todd. 1998-10-14. Hydrophilic membrane-based humidity control.. https://doi.org/10.1016/s0376-7388(98)00176-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monitoring of biofilm-associated Legionella pneumophila on different substrata in model cooling tower system.

Cooling towers have the potential to develop infectious concentrations of Legionella pneumophila. Legionella counts increases where biofilm and warm water temperatures are present. In this study, biofilm associated L. pneumophila and heterotrophic bacteria were compared in terms of material dependence. Model cooling tower system was experimentally infected by L. pneumophila standard strain and monthly monitored. Different materials were tested for a period of 180 days. The lowest L. pneumophila and heterotrophic plate counts were measured on plastic polymers, whereas L. pneumophila and heterotrophic bacteria were accumulated rapidly on galvanized steel surfaces. It can be concluded that selection of plastic polymers, as a manufacturing material, are suitable for recirculating water systems.

Air Conditioning↗

Real-time evaluation of ventilation filter-bank systems.

This study evaluated two government facility ventilation systems. One was a metropolitan government office complex with a recirculation system where outside air was the makeup air; the other was a NIOSH facility that used 100% outside air with no recirculation. The methodology employed was a modified American Society of Agricultural Engineers standard (S525) for testing total enclosure filtration efficiency, in agricultural tractor cabs, with optical particle counters (OPC). The low-efficiency bag filters were tested when new and after being in the ventilation system for 3 months. The replacement medium-efficiency filters were evaluated for 6 months (the manufacturer's suggested change-out schedule). These eight-chamber, medium-efficiency filters had an increased filter surface area that resulted in increased airflow through the system. Unfortunately, these filters contained electrostatic filter media and lost filtration efficiency rapidly, which was subsequently confirmed in a 30-day study conducted to determine an appropriate change-out schedule for the eight-chamber bag filters. The study determined that less than 6 months' use was justified due to the reduced efficiency of the electrostatic filter media. The NIOSH facility's air handler #8 (100% outside air unit) was upgraded from electrostatic bag filters, which had a suggested 9-month change-out schedule, to V Bank mechanical, wet-laid, glass fiber filters. The results of a 3-year evaluation showed that the V Bank filters had better filter efficiency after 3 years of service than the electrostatic filters had at 9 months. Both studies employed matched OPC instruments to reduce instrument-to-instrument bias. The methodology is adaptable to monitoring the total efficiency of most air filtration systems, and results can help make decisions about upgrading filter performance.

Air Conditioning↗

Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems.

We evaluated a ready-to-use real-time quantitative Legionella pneumophila PCR assay system by testing 136 hot-water-system samples collected from 55 sites as well as 49 cooling tower samples collected from 20 different sites, in parallel with the standard culture method. The PCR assay was reproducible and suitable for routine quantification of L. pneumophila. An acceptable correlation between PCR and culture results was obtained for sanitary hot-water samples but not for cooling tower samples. We also monitored the same L. pneumophila-contaminated cooling tower for 13 months by analyzing 104 serial samples. The culture and PCR results were extremely variable over time, but the curves were similar. The differences between the PCR and culture results did not change over time and were not affected by regular biocide treatment. This ready-to-use PCR assay for L. pneumophila quantification could permit more timely disinfection of cooling towers.

Air Conditioning↗