Argon plasma coagulation for rectal bleeding after prostate brachytherapy.

Abstract

PURPOSE: To better define the efficacy and safety of argon plasma coagulation (APC), specifically for brachytherapy-related proctitis, we reviewed the clinical course of 7 patients treated for persistent rectal bleeding. Approximately 2-10% of prostate cancer patients treated with 125I or 103Pd brachytherapy will develop radiation proctitis. The optimum treatment for patients with persistent bleeding is unclear from the paucity of available data. Prior reports lack specific dosimetric information, and patients with widely divergent forms of radiation were grouped together in the analyses. METHODS AND MATERIALS: Seven patients were treated with APC at the Veterans Affairs Puget Sound Health Care System and the University of Washington from 1997 to 1999 for persistent rectal bleeding due to prostate brachytherapy-related proctitis. Four patients received supplemental external beam radiation, delivered by a four-field technique. A single gastroenterologist at the Veterans Affairs Puget Sound Health Care System treated 6 of the 7 patients. If the degree of proctitis was limited, all sites of active bleeding were coagulated in symptomatic patients. An argon plasma coagulator electrosurgical system was used to administer treatments every 4-8 weeks as needed. The argon gas flow was set at 1.6 L/min, with an electrical power setting of 40-45 W. RESULTS: The rectal V100 (the total rectal volume, including the lumen, receiving the prescription dose or greater) for the 7 patients ranged from 0.13 to 4.61 cc. Rectal bleeding was first noticed 3-18 months after implantation. APC (range 1-3 sessions) was performed 9-22 months after implantation. Five patients had complete resolution of their bleeding, usually within days of completing APC. Two patients had only partial relief from bleeding, but declined additional APC therapy. No patient developed clinically evident progressive rectal wall abnormalities after APC, (post-APC follow-up range 4-13 months). CONCLUSIONS: Most patients benefited from APC, and no cases of clinically evident progressive tissue destruction were noted. Although APC appears to be efficacious and safe in the setting of the rectal doses described here, caution is in order when contemplating APC for brachytherapy patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Smith, K Wallner, J A Dominitz, B Han, L True, S Sutlief, K Billingsley. 2001-11-01. Argon plasma coagulation for rectal bleeding after prostate brachytherapy.. https://doi.org/10.1016/s0360-3016(01)01704-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ab initio study of spectroscopic properties of CuAr, CuAr(+) and CuAr(-).

The spectroscopic properties of CuAr, CuAr(+) and CuAr(-) have been studied in detail using ab initio MP2, CCSD and CCSD(T) methods. The effect of basis set on spectroscopic properties of these molecular systems has also been investigated. Among these molecules, CuAr(+) is found to be more strongly bound than CuAr and CuAr(-). The spectroscopic properties of CuAr and CuAr(-) are calculated in Lennard-Jones potential and the spectroscopic properties of CuAr(+) are calculated in Morse potential. Most of the spectroscopic constants of CuAr, CuAr(+) and all the spectroscopic constants of CuAr(-) are first reported. Our calculated bond length, harmonic frequency and dissociation energy of CuAr and CuAr(+) agree very well with the existing theoretical results.

Argon↗

Bacterial inactivation using a low-temperature atmospheric plasma brush sustained with argon gas.

This study investigated the bacterial inactivation/sterilization effects of a new atmospheric plasma source, which is a brush-shaped argon glow discharge created under 1 atm pressure. Such an atmospheric plasma brush requires extremely low power of less than 20 W to operate; and therefore is essentially a low-temperature discharge as confirmed by gas-phase temperature measurements. Two bacteria, Escherichia coli (E. coli) and Micrococcus luteus (M. luteus), seeded in various media were subjected to plasma treatment and their survivability was examined. It was found that such argon atmospheric plasma brush is very effective in destruction of the bacteria cells. With nutrient broth and standard methods agar as supporting media, a cell reduction in a level of 6 orders of magnitude was observed for E. coli within 3-4 min plasma treatment. A similar level of cell reduction was also observed for M. luteus in the two media with 2 or 3 min plasma treatment. The plasma treatment effects on the bacteria cell structures were also examined using scanning electron microscopy and the cell structure damages due to the plasma exposure were observed on both bacteria. The possible sterilization mechanism of the argon plasmas is also discussed in this article.

Argon↗

Biofilm formation on surface characterized micro-implants for skeletal anchorage in orthodontics.

Micro-implants are increasingly popular in clinical orthodontics to effect skeletal anchorage. However, biofilm formation on their surfaces and subsequent infection of peri-implant tissues can result in either exfoliation or surgical removal of these devices. The present study aimed to assess biofilm formation on five commercially available, surface characterized micro-implant systems in vitro. The elemental surface compositions of as-received and autoclave-sterilized micro-implants were characterized by X-ray photoelectron spectroscopy. High carbon contamination was detected on the oxide surfaces, along with traces of inorganic elements (Ca, Cu, Cr, Pb, Zn, and P) which disappeared after Ar(+) ion sputtering. The mean surface roughnesses (R(a)) were around 182nm for titanium micro-implants, and 69nm for stainless steel micro-implants, as measured by atomic force microscopy. Scanning electron microscopy revealed different surface topographies between manufacturers, varying from typical machined grooves to structural defects like pores and pits. Overnight biofilms were grown on micro-implant surfaces by immersion in pooled human whole saliva. Biofilms on micro-implants treated with chlorhexidine and fluoride mouthrinses contained comparable numbers of viable organisms, but significantly less than did untreated micro-implants. Comparison of different implant systems using multiple linear regression analysis indicated that biofilm formation was governed by roughness of the implant surface and the prevalence of carbon- and oxygen-rich components.

Argon↗