PubMed Health⌕ Search

PubMed · 11600124

A new distal targeting device for closed interlocking nailing.

Abstract

A new, image-intensifier mounted target device for closed interlocking nailing is described. The aim of locating the distal holes with the least radiation exposure is achieved. The proposed device has been designed to be mounted on the image-intensifier, is absolutely stable, eliminates the need for a specialised X-ray technician and allows the surgeon to be away from the radiation beam (direct or scattered). It also permits image intensification in the anteroposterior view, without losing the target. The device has proved its reliability in the operating room during closed interlocking nailing procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Tyropoulos, C Garnavos. 2001. A new distal targeting device for closed interlocking nailing.. https://doi.org/10.1016/s0020-1383(01)00021-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intramedullary fixation of tibial shaft fractures using an expandable nail.

Interlocking intramedullary nails are the gold standard for treating tibial fractures. We compared the clinical and economic factors associated with tibial fracture fixation using either interlocking intramedullary or expandable nails. From 2000 to 2002, 53 patients with 53 diaphyseal tibial fractures of similar characteristics (AO/OTA 42A1-B3) were randomly and prospectively treated with either interlocking (n = 26) or expandable nails (n = 27). Patients were followed for a minimum of 2 years. The mean surgical duration was 104 minutes with interlocking nails and 52.9 minutes with expandable nails. Rehospitalizations were required in 12 patients (46%) and reoperations were required in nine patients (35%) with interlocking nails. Only one patient (3%) with an expandable nail required rehospitalization and reoperation. Union was achieved after 17 weeks (mean) with interlocking nails and 11.5 weeks with expandable nails. The beneficial economic ramifications of using expandable nails were a 39% reduction in overall surgical and hospital expenses. Expandable nails showed important clinical advantages for tibial fracture fixation, and complications related to lengthy operations, reoperations, and rehospitalizations were substantially reduced. Overall treatment cost was substantially lower with expandable nails. Based on these advantages, simplicity in use, and short surgical time, we recommend an expandable nail for treating tibial (AO Type A, B) shaft fractures.

Bone Nails↗

Fractured neck of femur in a child after femoral fracture fixation by intramedullary flexible nails: a case report.

Since the introduction of flexible intramedullary nails, the treatment of femoral shaft fractures in adolescents has been revolutionized and this has become the routine treatment in most units, with minimal complications. We report a rare complication of an ipsilateral fractured neck of femur in a fit and healthy 12-year-old girl 6 months after treatment of a traumatic fractured femoral shaft; this was treated effectively with cannulated screws and the patient was successfully discharged without any further complication.

Bone Nails↗