PubMed HealthSearch

PubMed · 116385

Platelet aggregation: newly quantified using non-empirical parameters.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A R Nichols, H B Bosmann. 1979-08-31. Platelet aggregation: newly quantified using non-empirical parameters.. https://pubmed.ncbi.nlm.nih.gov/116385/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The urinary excretion of solvents and gases for the biological monitoring of occupational exposure: a review.

'In the field' application of the measurement of urinary excretion of unmodified solvent for the biological monitoring of exposed workers has been investigated in many recent papers. The results obtained for several solvents are reviewed. The values of correlation coefficients (r) and regression lines obtained for benzene, toluene, xylene, styrene, n-hexane, cyclohexane, 2- and 3-methylpentane, methyl chloride, tetrachloroethylene, carbon tetrachloride, methyl chloroform, p-dichlorobenzene, nitrous oxide, halothane, isoflurane, enflurane, acetone, methyl ethyl ketone and methyl isobutyl ketone are presented. The correlations observed were generally good: r values range from 0.50-0.97, and the majority are between 0.84 and 0.90. The regression lines reported for the same solvent in different studies present some variability: this is possibly due to an inadequate control of factors influencing the relationship between external dose and absorption, such as differences in body burden, work load, individual characteristics, etc. These factors are discussed. As a whole, results reported in the literature show that measuring of urinary excretion of unmodified solvents provides a highly sensitive and specific exposure index, and can also be applied for the biological monitoring of occupational exposure to low levels of solvents or to solvent mixtures. Nevertheless, for an adequate assessment of biological limit values, further studies evaluating the reproducibility of regression lines are needed, given that the aspects influencing the correlation between external dose and urinary excretion are fully controlled. Another crucial aspect is the correlation with early effects: even though this has yet to be evaluated for several solvents, for others such as styrene and perchloroethylene a good correlation was obtained, further supporting the usefulness of the measurement of urinary excretion of solvent for the biological monitoring of occupational exposure.

Absorption

A novel device for capturing breath samples for solvent analysis.

We have developed a novel breath sampling device suitable for capturing a portion of end-tidal air. This breath sample is then transferred onto a Perkin Elmer automated thermal desorption (ATD) sampling tube which is subsequently analysed by ATD-gas chromatography-mass spectrometry (GCMS). The breath sampler has been evaluated in the laboratory, in brief field trials and in human volunteer studies. The method is sensitive with a typical detection limit of 1 nmol/l and reproducible with an overall coefficient of variation between 5% and 15% for collection and analysis of breath samples from volunteers. The field trials used the sampler to assess exposure to solvents in several industries including the shoe manufacturing industry, the inks and coatings industry and at dry cleaning establishments. The sampler was found easy to use and reliable. Solvents detected include ethyl acetate (6.4-25.5 nmol/l), propan-2-ol (3.4-39.3 nmol/l), 2-butanone (0-6.6 nmol/l) and tetrachloroethene (0-557 nmol/l). The breath sampler was also used to monitor the elimination of solvents in breath from human volunteers after exposure chamber studies. More than 500 breath samples have been analysed from 24 volunteers in exposures to 10 different solvents (toluene, trimethyl benzene, tetrachloroethene, tetrahydrofuran, acetone, propan-2-ol, xylene, 2-butanone, 1-methoxy-2-propanol and n-hexane). The breath sampler allowed the rapid and non-invasive collection of data on elimination of solvents.

Absorption

Biological monitoring of experimental human exposure to trimethylbenzene.

Trimethylbenzene (TMB) is a component of numerous commercial preparations of organic solvents (Farbasol, Solvesso, Shellsol) used in the chemical, plastics, printing and other industries. TMB is a mixture of three isomers (pseudocumene-1,2,4-TMB; mesitylene-1,3,5-TMB; hemimellitene-1,2,3-TMB). The proportion of individual isomers in the mixture differs. The aim of this study was to obtain toxicokinetic data on the absorption and elimination of trimethylbenzene and its metabolites in biological fluids and to investigate the relationship between the biological indices of exposure and the absorbed dose. Eight-hour inhalation tests were performed in a toxicological chamber, The subjects were eight volunteers aged 20-39 with no history of exposure to TMB. They were exposed to pseudocumene, mesitylene or hemimellitene at concentrations ranging from 5 to 150 mg/m3 air. Exhaled air, capillary blood and urine samples were collected before, during and after the exposure. The determinations of TMB or its metabolites were performed using gas chromatography (HP 5890 II Plus, MSD, FID). Pulmonary ventilation in the volunteers ranged from 0.56 to 1.0 m3/h. The retention of 1,2,4-TMB; 1,3,5-TMB; 1,2,3-TMB in the lungs was 68%, 67% and 71%, respectively. The elimination of TMB from capillary blood occurred in accordance with the open three-compartment model. Urinary excretion of dimethylbenzoic acids (DMBA) proceeded according to the open two-compartment model. Based on the toxicokinetic data, a simulation model of accretion and excretion of DMBA in urine during a 14-day period was developed. The highest rates of metabolite excretion and the highest quantities of DMBA in urine during 24-h intervals were observed on day 5 of exposure. The relationship between the levels of TMB or DMBA in biological material and TMB air concentration or absorbed dose were determined. To select the urine fraction suitable for determining occupational TMB exposure, linear regression analysis was performed. The biological exposure limit (BEL) for TMB has been proposed, with the current maximum allowable concentration (MAC) value of 100 mg/m3 (Polish standard) baseline value.

Absorption