PubMed Health⌕ Search

PubMed · 11679147

The evidence for secretion clearance techniques.

Abstract

Many acute and chronic respiratory diseases are associated with increased respiratory secretions in the airways. Narrative reviews and a few systematic reviews of secretion clearance techniques have been published. These reviews raise concerns regarding the lack of evidence to support the various secretion clearance techniques. I conducted a comprehensive MEDLINE search of the following subjects: chest physical therapy, chest physiotherapy, postural drainage, forced expiratory technique, autogenic drainage, high-frequency chest wall compression, flutter device and secretions, positive expiratory pressure and secretions, intrapulmonary percussion, mechanical in-exsufflation and secretions. This was followed by a comprehensive search of cross-references to identify additional studies. The results of this review are reported herein. There are a number of methodological limitations of the literature reporting studies of the use of secretion clearance techniques. Most of the studies were small, most used crossover designs, and few used sham therapy. Many studies were limited to short-term outcomes such as sputum clearance with a single treatment session. Despite the clinical observation that retained secretions are detrimental to respiratory function and despite anecdotal associations between secretion clearance and improvements in respiratory function, there is a dearth of high-level evidence to support any secretion clearance technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D R Hess. 2001. The evidence for secretion clearance techniques.. https://pubmed.ncbi.nlm.nih.gov/11679147/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗