Optimal ECG trigger point in electron-beam CT studies: three methods for minimizing motion artifacts.

Abstract

RATIONALE AND OBJECTIVES: The authors hypothesized that electrocardiographic triggering near end systole could minimize motion artifacts in electron-beam computed tomography (CT) of the coronary artery. MATERIALS AND METHODS: The study included 2,660 patients who underwent coronary artery calcium scanning with electron-beam CT. Trigger times were as follows: end of T wave, 120 to 25 msec before end of T wave, 25-50 msec after end of T wave, 40%, 45%, 50%, 55%, 60%, 70%, 75%, 80%, 90%, and 100% of R-R interval. The authors divided each group into seven subgroups according to heart rate. The percentages of cases with motion artifact in the right coronary artery were computed. Optimal trigger times were defined for each group, as well as for scan acquisitions of 250 and 200 msec. RESULTS: The optimal trigger times were as follows for heart rates of less than 50, 51-60, 61-70, 71-80, 81-90, 91-100, and more than 100 beats per minute, respectively: for 100-msec scans, 359 (27% of the R-R interval), 228 (31%), 314 (34%), 304 (38%), 289 (41%), 283 (45%), and 274 msec (48%) after the R wave; for 250-msec scans, 840 (63%), 654 (60%), 240 (26%), 224 (28%), 219 (31%), 208 (33%), and 200 msec (35%) after the R wave; and for 200-msec scans, 722 (65%), 687 (63%), 249 (27%), 248 (31%), 244 (35%), 233 (37%), and 223 msec (39%) after the R wave. CONCLUSION: The use of these new electrocardiographic triggers before end systole yielded the lowest percentage of motion artifacts (<3% across all heart rates), much lower than for conventional triggers (51% of cases with motion artifact for 80% trigger, P < .001).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Mao, M J Budoff, L Bin, S C Liu. 2001. Optimal ECG trigger point in electron-beam CT studies: three methods for minimizing motion artifacts.. https://doi.org/10.1016/s1076-6332(03)80722-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2&#x2009;&#xb5;m &#xd7; 2&#x2009;&#xb5;m resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗