Time-shift estimation and focusing through distributed aberration using multirow arrays.

Abstract

The effects of element height on time-shift estimation and transmit focus compensation are demonstrated experimentally. Multirow ultrasonic transducer arrays were emulated by combining adjacent elements of a 3.0-MHz, 0.6-mm pitch, two-dimensional array to define larger virtual elements. Pulse-echo data were acquired through tissue-mimicking distributed aberrators, and time-shift maps estimated from those data were used for transmit focus compensation. Compensated beams formed by arrays with fine row pitches were similar, but focus restoration was significantly less effective for "1.75-D" arrays with a coarse row pitch. For example, when focus compensation was derived from strongly aberrated random scattering data [70-ns nominal rms arrival time fluctuation with 7 mm FWHM (full-width at half-maximum) correlation length], the mean -20 dB lateral beamwidths were 5.2 mm for f/2.0 arrays with 0.6- and 1.8-mm row pitches and 9.5 mm for an f/2.0 array with 5.4-mm pitch. Time-shift maps estimated from random scattering data acquired with 5.4-mm pitch arrays included large discontinuities caused by low correlation of signals received on vertically and diagonally adjacent emulated elements. The results indicate that multirow arrays designed for use with aberration correction should have element dimensions much less than 75% of the correlation length of the aberration and perhaps as small as 25 to 30% of the correlation length.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Lacefield, R C Waag. 2001. Time-shift estimation and focusing through distributed aberration using multirow arrays.. https://doi.org/10.1109/58.971712

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of scatter factors for 4, 6, 10, and 23 MV x rays at scattering angles between 30 degrees and 135 degrees.

NCRP Report No. 49, published in 1976, describes how to calculate the shielding for the medical use of x rays and gamma rays for energies up to 10 MV, including primary, scattered, and leakage radiation. However, in that report, data for scattered radiation for linear accelerators exist only for 6 MV, and leakage radiation is assumed, incorrectly, to be equivalent to primary radiation. Since the publication of that report, linear accelerators with energies up to 25 MV have been widely used in the radiation therapy community. Thus, there is a need to measure additional data for all energies in the range 4-25 MV. In this study, measurements were made of the "a" factor for 4, 6, 10, and 23 MV x rays at scattering angles between 30 degrees and 135 degrees. The results show that the 6 and 10 MV "a" factor data are consistent with published data, and the 23 MV data are also consistent with recently published data at 18 and 25 MV. The data show that, in general, the "a" factor decreases with energy; the exception is that 23 MV data show a sharp increase at low scattering angles, much greater than at other energies.

Scattering, Radiation↗

Scatter fraction: measurement and correction.

The concept of scatter in Positron Emission Tomography is reviewed regarding origin and influence on data. Different ways to measure and correct for scatter are discussed.

Scattering, Radiation↗