PubMed Health⌕ Search

PubMed · 11831766

Two-step solvent gradients in simulated moving bed chromatography. Numerical study for linear equilibria.

Abstract

The application of gradients in simulated moving bed (SMB) chromatography has recently attracted interest as a method for further improving the performance of this continuous separation process. One possible implementation of gradients consists in setting the solvent strength in the desorbent stream higher than that in the feed stream. As a result, the components to be separated are more retained in the zones upstream of the feed position and more easily eluted in the zones downstream of the feed position. If a liquid mobile phase is used, gradients can be created by dosing different solvents into the feed and desorbent ports. In a closed-loop gradient SMB arrangement the solvent strength within the unit will depend on the two feed compositions and on the characteristic flow-rates of the process. In this work an equilibrium stage model describing a true moving bed process is used to analyze numerically the main features of a two-step gradient SMB process. The adsorption isotherms are assumed to be always linear under isocratic conditions. The relevant Henry constants depend in a nonlinear manner on the composition of the solvent. Based on numerical simulations the impact of the two inlet solvent compositions is demonstrated in terms of the size and shape of regions of applicable flow-rates. Different strategies of designing the process are discussed and compared with respect to maximizing productivities and minimizing desorbent requirements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dorota Antos, Andreas Seidel-Morgenstern. 2002-01-25. Two-step solvent gradients in simulated moving bed chromatography. Numerical study for linear equilibria.. https://doi.org/10.1016/s0021-9673(01)01365-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Solid-phase extraction-electrospray ionization mass spectrometry for the quantification of folate in human plasma or serum.

The measurement of 5-methyltetrahydrofolic acid (5 MT) blood levels is one of several factors used to diagnose folate deficiency in humans. 5 can be selectively purified from either human plasma or human serum via solid-phase extraction procedures and specifically detected and quantified in the extracts with liquid chromatography/isotope-dilution electrospray-ionization mass spectrometry. Two different, yet complementary, solid-phase extraction-liquid chromatography/mass spectrometry methods have been developed and applied to the quantification of 5 MT from such extracts. One method utilizes the high-affinity folate-binding protein from cow's milk coupled with multiple-reaction-monitoring-mode tandem mass spectrometry while the other method utilizes reversed-phase C(18) extraction followed by selected-ion-monitoring-mode mass spectrometry. The accuracy of each method is assessed through a comparative determination of 5 MT levels in homogenous plasma and serum pools. Additionally, each method is compared and evaluated against the "total folate" results provided by routine radioassay and microbiological assay determinations. On the basis of the experimental data presented in this report, it is suggested that both methods have the capacity to serve as potential reference methods for the quantification of circulating 5MT in plasma or serum.

Chromatography, Liquid↗

Analytical derivatization-a tool for determination of orotic acid.

Derivatization of orotic acid (OA) into various forms (trimethylsilylderivate, alkyl ester and per-methylated derivate) and their evaluation by GC/MS is described. The tested approach includes ion-exchange SPE clean-up, evaporation and chemical reaction with different types of derivatization agents (N,O-bis-(trimethylsilyl)trifluoroacetamide with trimethylchlorosilane, butanol with acetylchloride and ethereal solution of diazomethane). Derivate originated in the reaction with diazomethane was used for determination of urinary orotic acid by GC/MS. Detection limit of 0.28 micromol l(-1) was reached using the ion 82 m/z in single ion monitoring (SIM) mode. Linearity of the method was tested within the range of 3.4-2503.4 micromol l(-1) covering physiological and pathological levels of orotic acid in urine sample. Recoveries were within the range 93.7-110.6%. Application of the method on the patient with defect of ornithine transcarbamylase (OTC) was demonstrated as well.

Chromatography, Liquid↗