PubMed Health⌕ Search

PubMed · 11973490

UK audit of single photon emission computed tomography reconstruction software using software generated phantoms.

Abstract

The purpose of this study was to undertake an audit of the quantitative characteristics of single photon emission computed tomography software using projection data from an analytically generated software phantom and a measured line source. The phantom consisted of three structures. A uniformly filled cylinder, a series of cylindrical rods of various diameters in a background activity with a rod to background ratio of 2:1 and lastly, a set of three concentric rings of activity in the ratio 1:0:1. The phantom contained no added statistical noise. No attenuation was imposed on the data. The phantom was generated analytically and projections were distributed at six different count densities. A single set of projections from a thin line source was also distributed. These data were distributed to centres throughout the UK. Centres were asked to reconstruct the data using a 'ramp only' reconstruction with no additional smoothing function applied. Data were requested for mean and standard deviation in the uniform cylinder, the maximum counts for each cylindrical rod and the mean counts in regions placed within the concentric rings. For the measured line source, centres were asked to measure the full width at half maximum and peak pixel counts for a profile through the reconstructed line. Results from 115 systems were obtained from 100 centres throughout the UK. These provided data from 12 software providers, 11 of these being commercial companies. Data were compared with the known input values and histograms of the distribution of results obtained. Significant differences in quantitative parameters were noted for the different input count densities as well as between suppliers and revisions of software from single suppliers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P H Jarritt, D R Whalley, J V Skrypniuk, A S Houston, J S Fleming, P S Cosgriff. 2002. UK audit of single photon emission computed tomography reconstruction software using software generated phantoms.. https://doi.org/10.1097/00006231-200205000-00009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Generating correlated data for omics simulation.

Simulation of realistic omics data is a key input for benchmarking studies that help users obtain optimal computational pipelines. Omics data involves large numbers of measured features on each sample and these measures are generally correlated with each other. However, simulation too often ignores these correlations, perhaps due to computational and statistical hurdles of doing so. To alleviate this, we describe three approaches for generating omics-scale data with correlated measures which mimic real datasets. These approaches are all based on a Gaussian copula approach with a covariance matrix that decomposes into a diagonal part and a low-rank part. This decomposition allows for extremely efficient simulation, overcoming a hurdle for adoption of past methods. We use these approaches to demonstrate the importance of including correlation in two benchmarking applications. First, we show that variance of results from the popular DESeq2 method increases when dependence is included. Second, we demonstrate that CYCLOPS, a method for inferring circadian time of collection from transcriptomics, improves in performance when given gene-gene dependencies in some circumstances. We provide an R package, dependentsimr, that has efficient implementations of these methods and can generate dependent data with arbitrary marginal distributions, including discrete (binary, ordered categorical, Poisson, negative binomial), continuous (normal), or with an empirical distribution.

Computer Simulation↗

Addressing current challenges in cancer immunotherapy with mathematical and computational modelling.

The goal of cancer immunotherapy is to boost a patient's immune response to a tumour. Yet, the design of an effective immunotherapy is complicated by various factors, including a potentially immunosuppressive tumour microenvironment, immune-modulating effects of conventional treatments and therapy-related toxicities. These complexities can be incorporated into mathematical and computational models of cancer immunotherapy that can then be used to aid in rational therapy design. In this review, we survey modelling approaches under the umbrella of the major challenges facing immunotherapy development, which encompass tumour classification, optimal treatment scheduling and combination therapy design. Although overlapping, each challenge has presented unique opportunities for modellers to make contributions using analytical and numerical analysis of model outcomes, as well as optimization algorithms. We discuss several examples of models that have grown in complexity as more biological information has become available, showcasing how model development is a dynamic process interlinked with the rapid advances in tumour-immune biology. We conclude the review with recommendations for modellers both with respect to methodology and biological direction that might help keep modellers at the forefront of cancer immunotherapy development.

Computer Simulation↗

Degradation of supercoiled plasmid DNA within a capillary device.

Supercoiled plasmid DNA is susceptible to fluid stress in large-scale manufacturing processes. A capillary device was used to generate controlled shear conditions and the effects of different stresses on plasmid DNA structure were investigated. Computational fluid dynamics (CFD) analysis was employed to characterize the flow environment in the capillary device and different analytical techniques were used to quantify the DNA breakage. It was found that the degradation of plasmid DNA occurred at the entrance of the capillary and that the shear stress within the capillary did not affect the DNA structure. The degradation rate of plasmids was well correlated with the average elongational strain rate or the pressure drop at the entrance region. The conclusion may also be drawn that laminar shear stress does not play a significant role in plasmid DNA degradation.

Computer Simulation↗