Rapid depth dose determination by a computer-controlled dosimetry system.

Abstract

A comprehensive depth dose measuring system controlled by a small computer has been designed to enable full depth dose information for a linear accelerator to be obtained within one day. An ionization microchamber is moved rapidly under computer control in a horizontal plane to preselected points within a water phantom by two stepping motors to a spatial resolution of 0-025 mm. The ionization current pulses are converted to DC voltages by an interface providing complete charge integration and yet having a rapid response to drastic changes in dose level. These are fed to the computer for analysis and subsequent conversion to depth dose data. The chamber path follows a preselected fan-shaped grid after automatic determination of the X-ray beam central axis. The combination of rapid chamber motion with halts for charge integration and computer sampling has resulted in fast data acquisition independent of measurement response times. This information, which is stored on disc, can be directly read by a treatment planning program. The overall accuracy of measurement lies within 0-5% of the true depth dose at any point. Central axis and transverse profiles can be assessed at the time of measurement through visualization on the computer storage oscilloscope.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D O Bottrill, M J Nieman, A T Redpath. 1975. Rapid depth dose determination by a computer-controlled dosimetry system.. https://doi.org/10.1088/0031-9155%2F20%2F6%2F010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of sites for the location of WEEE recycling plants in Spain.

As a consequence of new European legal regulations for treatment of waste electrical and electronic equipment (WEEE), recycling plants have to be installed in Spain. In this context, this contribution describes a method for ranking of Spanish municipalities according to their appropriateness for the installation of these plants. In order to rank the alternatives, the discrete multi-criteria decision method PROMETHEE (Preference Ranking Organisation METHod for Enrichment Evaluations), combined with a surveys of experts, is applied. As existing plants are located in North and East Spain, a significant concentration of top ranking municipalities can be observed in South and Central Spain. The method does not present an optimal structure of the future recycling system, but provides a selection of good alternatives for potential locations of recycling plants.

Computers↗

Overview of informatics for high content screening.

With the growing use of high content screening (HCS) and analysis in drug discovery and systems biology, informatics has come to the forefront as a critical technology to effectively utilize the massive volumes of high content data and images being generated. Informatics technologies are required to transform HCS data and images into useful information and then into knowledge to drive decision making in an efficient and cost effective manner. In this chapter, we provide an overview of informatics tools and technologies for HCS, discuss some of the challenges of harnessing the huge and growing volumes of HCS data, and provide insight to help toward implementing or selecting, and utilizing a high content informatics solution to meet your organization's needs.

Computers↗