PubMed Health⌕ Search

PubMed · 12085389

Presternal peritoneal catheter.

Abstract

The swan neck presternal catheter is composed of 2 flexible (silicon rubber) tubes joined by a titanium connector at the time of implantation. The exit site is located in the parasternal area. The catheter located on the chest was designed to reduce the incidence of exit site infections compared to peritoneal dialysis catheters with abdominal exits. From August 1991 to September 30, 2001, 974 swan neck presternal catheters were implanted worldwide. At the university of Missouri, 150 of these catheters were implanted and followed for over 130 patient years. Presternal catheters tended to perform better than swan neck abdominal catheters regarding exit and tunnel infections, even though they were implanted in several patients in whom regular catheters with the exit on the abdomen would be difficult or impossible to implant. Two-year survival probability of presternal catheters was 0.95. Recurrent/refractory peritonitis was the only reason for catheter failure. The catheter is particularly useful in obese patients (body mass index >35), patients with ostomies, children with diapers and fecal incontinence, and patients who want to take baths without the risk of exit contamination. Many patients prefer presternal catheter because of better body image. Disadvantages of the presternal catheter are minimal. Compared with abdominal catheters, dialysis-solution flow is slightly slower because of the increased catheter length; however, slower flow is insignificant clinically. There is a possibility of catheter disconnection in the tunnel, but this complication is extremely rare in adults and easily corrected. Finally, the implantation technique is more challenging compared with that of single-piece, abdominal catheters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zbylut J Twardowski. 2002. Presternal peritoneal catheter.. https://doi.org/10.1053/jarr.2002.33517

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The role of surgery in the management of septic shock--extra-abdominal causes of sepsis.

Septic shock is a severe inflammatory response to one or more pathogenic micro-organisms. When a person's immune response is excessively intense, a cascade of phenomena may be activated that ultimately is harmful. Appropriate management of septic shock may include surgical intervention to remove or neutralize the septic focus in an effort to treat the inflammatory response cascade. This is the first of two articles presenting current information on the role of surgery in the management of a patient with septic shock. This article describes extra-abdominal sources of sepsis.

Catheters, Indwelling↗

Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

Catheters, Indwelling↗