Abstract

Although the basic principles of flow cytometry have changed little in the past quarter century, the applications of this technology have evolved substantially. As in the past, cytometers interrogate individual cells or particles in a stream with a laser as the cells move past a set of stationary detectors. Increasingly, more colors of fluorescence are being detected by cytometers, faster analysis and sorting rates are becoming possible, cytometers capable of multidirectional sorting are being marketed, and more reagents are becoming available for a wide variety of applications. Furthermore, flow cytometry has not stopped evolving. The development of narrow spectrum flourescent probes, the integration of molecular biologic techniques with flow cytometry, and the evaluation of cell-free markers such as cytokines will be key components in the continuing evolution of flow cytometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Philip McCoy. 2002. Basic principles of flow cytometry.. https://doi.org/10.1016/s0889-8588(01)00015-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Issues in using databases of pre-recorded physiological signals to test medical devices.

Bench testing with databases of pre-recorded physiological signals is a common step in the verification and validation of medical devices. For example, in the case of an electrocardiographic (ECG) monitor to be tested, the physiological signals are ECG tracings that have previously been recorded from patients using other ECG monitors. Human overreaders then annotate the tracings to determine the occurrence of significant clinical events such as ventricular tachycardia. These annotations can be used to determine the sensitivity and specificity of the ECG monitor to be tested. This article aims to highlight some issues associated with such bench testing, such as the way the pre-recorded signals are presented to the medical device to be tested, the adequacy of single channel versus dual channel versus multi-channel testing in the bench testing, and the need for the human overreaders and the medical device to use the same set of rules for determining the occurrence of a clinical event. These issues are also applicable to other monitors such as the apnea monitor. Some suggestions for addressing the issues are presented.

Analog-Digital Conversion↗