New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging.

Abstract

Despite all promising advances, some challenges remain for ECG-gated multislice CT examinations of the heart and the coronary arteries with current 4-slice detectors: adequate visualization of stents and severely calcified coronary arteries, examination of patients with higher heart rates and patients, who cannot adequately hold their breath for at least 30 sec. The new generation of multislice CT systems offering simultaneous acquisition of up to 16 sub-millimeter slices and gantry rotation times shorter than 0.5 sec has the potential to overcome these limitations. We describe the technical principles of cardiac scanning with a state-of-the-art 16-slice CT equipment (SOMATOM Sensation 16, Siemens AG, Forchheim, Germany). We discuss an extension of the Adaptive Cardio Volume (ACV) reconstruction approach for ECG-gated multislice spiral CT. We show the impact of reduced gantry rotation time (0.42 sec) on temporal resolution, and we demonstrate the influence of slice width on the visualization of stents and plaques. Deviating from general purpose applications a cone-correction is not required for cardiac scanning with 16-slice CT systems. In addition to the absolute improvement, the temporal resolution shows a different dependence on the patient's heart rate for 0.42 sec rotation time, reaching its optimum (105 msec) at 81 BPM. This has the potential to expand the range of heart rates accessible to routine clinical examinations. Owing to sub-millimeter slice width and optimized in-plane resolution characteristics, visualization of stents and severe calcifications in coronary arteries is significantly improved. Clinical experience will be needed to fully evaluate the potential of 16-slice technology for cardiac imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Flohr, H Bruder, K Stierstorfer, J Simon, S Schaller, B Ohnesorge. 2002. New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging.. https://doi.org/10.1055/s-2002-32930

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗