PubMed Health⌕ Search

PubMed · 12243572

Element size effect on phase aberration correction.

Abstract

The distortion effect of tissue on ultrasonic beamforming is simplified as a 2-D time-shifting screen placed against the array surface. The ideal correction of such distortion requires a 2-D array with infinitesimally small elements. However, elements of finite sizes must be utilized in practice, causing the so-called residual phase error (RPE). As element size is reduced, the magnitude of the RPE is reduced, and its spatial feature becomes finer. Analyses have been performed to reveal that the magnitude of the RPE is proportional to the imaging frequency, the rms magnitude of the original time-delay error, and the diagonal size of individual rectangular elements, and is inversely proportional to the correlation length of the original time-delay error. Simulations have been performed to study the peak sidelobe level caused by the RPE as the element sizes are reduced. The sidelobe is defined here as the difference between the ideal beam (with no phase error) and the beam obtained in the presence of the RPE. For a multi-row array in which a conventional 1-D array is divided into N rows of independent elements in the elevation direction, the peak sidelobe level is found to vary approximately as N(-1) instead of the anticipated N(-2). The reduction is caused by the reduced magnitude of the RPE, and the finer spatial feature of the RPE, although apparent in the reduced spatial correlation length, does not result in additional reduction of the sidelobe level. The reason for this has been analyzed. The results of this study provide guidance for designing multi-row arrays suitable for phase aberration correction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D L Donald Liu. 2002. Element size effect on phase aberration correction.. https://doi.org/10.1109/tuffc.2002.1041537

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Implementation of continuous 3D whole-body PET scanning using on-the-fly Fourier rebinning.

The continuous scanning mode in three-dimensional (3D) whole-body PET studies has the advantage of axial sensitivity uniformity over the majority of the axial FOV. However, this scan mode requires large data handling compared to conventional discrete scans. In this work, we have implemented and evaluated a new continuous 3D scan method using 'on-the-fly' Fourier rebinning. In this method, sinograms for the pair of rings are added in real-time into the sinograms of the incremented ring pairs by moving the bed axially one detector width at a time. For an N-ring scanner, 2N--1 sinograms are transferred to a host computer at each bed position and rebinned into direct two-dimensional (2D) sinograms using Fourier rebinning. Phantom and human studies showed that the axial image uniformity is achieved without degrading the axial resolution. This method can minimize the time for off-line data processing and makes the continuous 3D scan more feasible in clinical whole-body studies.

Fourier Analysis↗

Analysis of phosphate position in hexose monosaccharides using ion-molecule reactions and SORI-CID on an FT-ICR mass spectrometer.

Through the use of ion-molecule reactions and SORI-CID, the phosphate position in hexose phosphate monosaccharides has been determined in the negative ion mode. Trimethyl borate was used as a reagent gas and was found to react readily with the phosphorylated hexose monosaccharides. After reaction of the reagent gas with the hexose phosphate, ion activation of the precursor by SORI-CID yielded different MS/MS spectra. Different diagnostic ions were generated for the two isomers, thus enabling differentiation and linkage position determination of the phosphate moiety.

Fourier Analysis↗