PubMed Health⌕ Search

PubMed · 12243581

Multilayer transducer transfer matrix formalism.

Abstract

A complete formulation of direct and inverse 4 x 4 transfer matrices for parallel and series, electrically connected, mechanically stacked, 1-D thickness mode multilayer piezoelectric transducers is presented. Complex coefficients account for the mechanical, dielectric, and piezoelectric losses. The direct or inverse 4 x 4 transfer matrix transfers quantities at the top surface into their values at the bottom surface or vice versa, respectively. The 4 x 4 transfer matrices derive from the 3 x 3 transfer matrices, which follow from the 3 x 3 matrix for the general three-port. For both parallel and series connections, the 3 x 3 and 4 x 4 direct and inverse transfer matrices are interrelated through transformation symmetries; also, the inverse matrix can be obtained from the direct matrix by changing the sign of both the piezoelectric coefficient and the explicitly occurring complex variable, j. For the electrically parallel-connected case, explicit voltage orientation reversals occur at successive piezoelectric layers. Cascading the 4 x 4 matrices yields the sum of the currents through the piezoelectric layers for the electrically parallel-connected case and the sum of the voltage differences across the layers for the electrically series-connected case. The resultant matrices are calculated for the cascading of n identical piezoelectric layers connected in parallel and series.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Philip E Bloomfield. 2002. Multilayer transducer transfer matrix formalism.. https://doi.org/10.1109/tuffc.2002.1041547

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Content uniformity and assay requirements in current regulations.

The acceptance of a tablet batch is based both on the content uniformity test and on the assay. It is shown that these two characteristics are not independent, and the acceptance criteria for them are not even consistent. For content uniformity range three methods of calculation are compared: the present European Pharmacopoeia method, a tolerance range method with improved k tolerance factor and a one-way random effects analysis of variance model. To resolve the inconsistency several options are discussed: applying the holistic content uniformity range alone; using content uniformity standard deviation and assay mean simultaneously or applying a criterion based on Taguchi's quadratic loss function.

Mathematics↗

Stable time filtering of strongly unstable spatially extended systems.

Many contemporary problems in science involve making predictions based on partial observation of extremely complicated spatially extended systems with many degrees of freedom and with physical instabilities on both large and small scale. Various new ensemble filtering strategies have been developed recently for these applications, and new mathematical issues arise. Because ensembles are extremely expensive to generate, one such issue is whether it is possible under appropriate circumstances to take long time steps in an explicit difference scheme and violate the classical Courant-Friedrichs-Lewy (CFL)-stability condition yet obtain stable accurate filtering by using the observations. These issues are explored here both through elementary mathematical theory, which provides simple guidelines, and the detailed study of a prototype model. The prototype model involves an unstable finite difference scheme for a convection-diffusion equation, and it is demonstrated below that appropriate observations can result in stable accurate filtering of this strongly unstable spatially extended system.

Mathematics↗