Macroradiography using conventional radiographic X-ray equipment.

Abstract

Macroradiography is a radiographic imaging technique used to increase the size of the image relative to that of the object. Macroradiographic images suffer degradation due mainly to geometric unsharpness (U(g)). U(g) results from the finite size of the focal spot of the X-ray tube. Specialized equipment with a small effective focal spot size (Eff FSS) is generally used to perform macroradiography. The specialized nature of the equipment means macroradiographic examinations are not commonly undertaken. Macroradiographic examinations can also be performed on conventional radiographic equipment because the Eff FSS varies in the X-ray beam along the cathode-anode axis. Calculations and measurements of FSSs at different positions along the cathode-anode direction of the X-ray beam have been made. A simple technique of angling the X-ray tube 10 degrees towards the cathode reduces the Eff FSS in one dimension while still maintaining a vertical central ray. Reduced beam coverage results from this technique and an increase in radiographic exposure is required to compensate for the anode heel effect. Macroradiographic images of line pair phantoms and a hand-wrist phantom, at various tube angles, have been obtained to compare image detail.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Davidson, S Bowman. 2002. Macroradiography using conventional radiographic X-ray equipment.. https://doi.org/10.1259/bjr.75.898.750831

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Content uniformity and assay requirements in current regulations.

The acceptance of a tablet batch is based both on the content uniformity test and on the assay. It is shown that these two characteristics are not independent, and the acceptance criteria for them are not even consistent. For content uniformity range three methods of calculation are compared: the present European Pharmacopoeia method, a tolerance range method with improved k tolerance factor and a one-way random effects analysis of variance model. To resolve the inconsistency several options are discussed: applying the holistic content uniformity range alone; using content uniformity standard deviation and assay mean simultaneously or applying a criterion based on Taguchi's quadratic loss function.

Mathematics↗

Stable time filtering of strongly unstable spatially extended systems.

Many contemporary problems in science involve making predictions based on partial observation of extremely complicated spatially extended systems with many degrees of freedom and with physical instabilities on both large and small scale. Various new ensemble filtering strategies have been developed recently for these applications, and new mathematical issues arise. Because ensembles are extremely expensive to generate, one such issue is whether it is possible under appropriate circumstances to take long time steps in an explicit difference scheme and violate the classical Courant-Friedrichs-Lewy (CFL)-stability condition yet obtain stable accurate filtering by using the observations. These issues are explored here both through elementary mathematical theory, which provides simple guidelines, and the detailed study of a prototype model. The prototype model involves an unstable finite difference scheme for a convection-diffusion equation, and it is demonstrated below that appropriate observations can result in stable accurate filtering of this strongly unstable spatially extended system.

Mathematics↗