A self consistent normalized calibration protocol for three dimensional magnetic resonance gel dosimetry.

Abstract

In a clinical setting, mixed and inconsistent results have been reported using Magnetic Resonance Relaxation imaging of irradiated aqueous polymeric gels as a three-dimensional dosimeter, for dose verification of conformal radiation therapy. The problems are attributed to the difficulty of identifying an accurate dose calibration protocol for each delivered gel at the radiation site in a clinical setting. While careful calibration is done at the gel manufacturing site in a controlled laboratory setting, there is no guarantee that the dose sensitivity of the gels remains invariant upon delivery, irradiation, magnetic resonance imaging and storage at the clinical site. In this study, we have compared three different dose calibration protocols on aqueous polymeric gels for a variety of irradiation scenarios done in a clinical setting. After acquiring the three-dimensional proton relaxation maps of the irradiated gels, the dose distributions were generated using the off-site manufacturer provided calibration curve (Cal-1), the on-site external tube gel calibration (Cal-2) and the new on-site internal normalized gel calibration (Cal-3) protocols. These experimental dose distributions were compared with the theoretical dose distributions generated by treatment-planning systems. We observed that the experimental dose distributions generated from the Cal-1 and Cal-2 protocols were off by 10% to 40% and up to 200% above the predicted maximum dose, respectively. On the other hand, the experimental dose distributions generated from the Cal-3 protocol matched reasonably well with the theoretical dose distributions to within 10% difference. Our result suggests that an independent on-site normalized internal calibration must be performed for each batch of gel dosimeters at the time of MR relaxation imaging in order to account for the variations in dose sensitivity caused by various uncontrollable conditions in a clinical setting such as oxygen contamination, temperature changes and shelf life of the delivered gel between manufacturing and MR acquisitions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richard L Cardenas, Kwan Hon Cheng, Lynn J Verhey, Ping Xia, Lorne Davis, Brian Cannon. 2002. A self consistent normalized calibration protocol for three dimensional magnetic resonance gel dosimetry.. https://doi.org/10.1016/s0730-725x(02)00596-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗