PubMed · 125041
Permanent sterilization by hysteroscopic cauterization.
Abstract
A small series of 22 patients who underwent hysteroscopy cauterization is reported. The uterus was distended with CO2 and dextran. Cauterization was done with a 6 mm. long, active-tip, No. 4 electrode: There was a 27 per cent failure rate for the controlled cases, this dropping to 11 per cent after recauterization. A significant complication, small bowel perforation, was treated by resection and anastomosis with complete recovery. The uterine distention with CO2 is safe but ostium visualization is not very good; Dextran distention is more cumbersone but gives excellent visualization and exposure of the ostium because higher intrauterine pressures are developed.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
L A Cibils. 1975-02-15. Permanent sterilization by hysteroscopic cauterization.. https://doi.org/10.1016/0002-9378(75)90083-6. https://pubmed.health/record/pubmed%3A125041/permanent-sterilization-by-hysteroscopic-cauterization
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.