PubMed Health⌕ Search

PubMed · 12542197

Decrease in cochlear blood flow with infusion of nitric oxide synthase inhibitor and its recovery with L-arginine infusion: comparison with abdominal blood flow and auricular blood flow.

Abstract

We observed changes in cochlear blood flow (CoBF), abdominal blood flow (AbBF) and auricular blood flow (AuBF) in rats after administration of the nitric oxide (NO) synthase inhibitor N-nitro-L-arginine-methyl ester (L-NAME). Ten min after i.v. infusion of L-NAME, L-arginine, a substrate of NO, was infused (100 mg/kg) intravenously. Using a laser Doppler flowmeter, changes in blood flow were recorded from the basal turn of the right cochlea, abdominal wall or right auricle, and systemic blood pressure (BP) was recorded simultaneously from the left femoral artery. As another parameter of vascular response, vascular conductance (VC) was calculated from blood flow/mean BP. I.v. infusion of L-NAME produced a dose-dependent depression of cochlear VC at concentrations of 0.2 (-18.9%), 1 (-37.9%), 5 (-45.8%) and 10 mg/kg (-48.3%). Infusion of L-arginine partially reversed the decrease of CoBF caused by L-NAME. The group that received a 0.2 mg/kg infusion of L-NAME showed the largest degree of recovery (23.8%) with L-arginine, while the 10 mg/kg group showed the smallest degree of recovery (10.1%). AbBF also decreased after infusion of L-NAME (5 mg/kg) but to a lesser degree (-41.1% depression of VC) and with no significance compared to the decrease in CoBF (5 mg/kg L-NAME). Likewise, AuBF showed a decrease (-44.0% depression of VC) after infusion of L-NAME (10 mg/kg), the decrease being less than that of CoBF (10 mg/kg L-NAME). Recoveries from these decreased levels of VC in the AbBF and AuBF groups appeared to be smaller than those in the CoBF groups at the same dose of L-NAME (5.5% vs 17.3% in abdominal VC; 5.3% vs 10.1% in auricular VC). In a previous study comparing the CoBF changes caused by i.v. infusion and round window application of L-NAME, we proposed that i.v. infusion of L-NAME in rats primarily affects the precapillary arteriole of the spiral modiolar artery, which effectively regulates cochlear microcirculation as a resistance artery. Thus we assume that there may exist an active pathway of the NO/soluble guanylate cyclase/cyclic guanosine monophosphate system in the above vessels. With regard to the finding of a smaller recovery of VC with L-arginine in both the AbBF and AuBF groups, we consider that differences in L-arginine availability or uptake, and in the synthesis of NO, may exist between the cochlear and cutaneous vasculatures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hideaki Hoshijima, Kazuo Makimoto. 2002. Decrease in cochlear blood flow with infusion of nitric oxide synthase inhibitor and its recovery with L-arginine infusion: comparison with abdominal blood flow and auricular blood flow.. https://pubmed.ncbi.nlm.nih.gov/12542197/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prenatal sonographic diagnosis of a rare Cantrell's pentalogy variant with associated open neural tube defect - a case report.

Cantrell's pentalogy is a very rare congenital anomaly. The hallmark of this condition is the presence of ectopia cordis and an abdominal wall defect. Its association with craniorachischisis is even more infrequent with just a few cases reported in the literature. The authors describe a case of a prenatal ultrasound diagnosis of Cantrell's pentalogy with posterior encephalocele and spinal dysraphism associated.

Abdominal Wall↗

Laparoscopically assisted components separation technique for ventral incisional hernia repair.

Reconstruction of the abdominal wall to repair ventral hernias continues to pose a challenge to surgeons due to relatively high rates of recurrence and morbidity. In 1990, Ramirez pioneered a technique of components separation of the abdominal wall for ventral hernia repair. Although an effective hernia repair, the mobilization of skin and subcutaneous tissue endangers the blood supply and predisposes midline skin to necrosis. The goal of this study is to determine whether releasing incisions in the transversus abdominis fascia and posterior rectus sheath provide adequate mobilization of the abdominal wall necessary for ventral hernia repair, thus paving the way for a laparoscopic component separation technique. Ten fresh cadavers were used and one side of the abdomen underwent the conventional Ramirez components separation: midline incision, dissection of skin and subcutaneous tissue off the anterior abdominal wall, and incisions in the external oblique aponeurosis and posterior rectus sheath, while the other side received incisions in the transversus abdominis fascia and the posterior rectus sheath with no undermining of the skin. The amount of fascial translation was measured after each incision. Incising only the external oblique aponeurosis produced greater mobilization of the abdominal wall at the level of the umbilicus (P = 0.02) and anterior superior iliac spine (ASIS, P = 0.029) than releasing only transversus abdominis fascia. More importantly, there was no statistically significant difference in the amount of release produced by the complete internal-release components separation versus the conventional technique. In order to test the feasibility of performing the procedure laparoscopically, one additional cadaver underwent a laparoscopic transversus abdominis fascia release. The procedure was successful and resulted in comparable amounts of fascial release as the other 10 cadavers. From this study, it appears technically feasible to perform a laparoscopic components separation to repair a ventral hernia and the procedure produces the same amount of release as the conventional open component separation technique.

Abdominal Wall↗

Long-lasting bioresorbable poly(lactic acid) (PLA94) mesh: a new approach for soft tissue reinforcement based on an experimental pilot study.

The purpose of this study was to evaluate host response and soft-tissue regeneration after poly(lactic acid) (PLA) mesh implantation in a rat model, in comparison with light-weight polypropylene (PPL) and poly(glycolic acid) (PGA) meshes. Full-thickness abdominal wall defects were created in 45 Wistar rats and reconstructed with 15 PLA(94), 15 PPL and 15 PGA meshes. Animals were killed on days 7, 30 and 90 to evaluate the presence of adhesions and changes in tensile strength of the implants. Histopathology and immunohistochemistry were performed to evaluate the collagen deposition and the inflammatory response. Statistics were done using unpaired Student's t-test, Mann-Whitney rank sum test, Student-Newman-Keuls test and Bonferroni (Dunn) t-test. The inflammatory response induced by the PLA mesh implantation was significantly milder than after PPL mesh. In PLA, vascularity and collagen organization was significantly higher than in PPL and PGA at 30 and 90 days, and collagen composition score was significantly higher than in PPL at 7 and 30 days. In PLA, shrinkage was significantly lower than in PPL and PGA at 7 and 30 days. Elongation at break and tensile strength were comparable between PLA and PPL over the 90-day period. The PLA mesh induces a milder inflammatory response, more orderly collagen deposition than PPL, and preserved comparable tensile strength after 90 days.

Abdominal Wall↗