PubMed Health⌕ Search

PubMed · 12564874

Efficient model-based quantification of left ventricular function in 3-D echocardiography.

Abstract

Quantitative functional analysis of the left ventricle plays a very important role in the diagnosis of heart diseases. While in standard two-dimensional echocardiography this quantification is limited to rather crude volume estimation, three-dimensional (3-D) echocardiography not only significantly improves its accuracy but also makes it possible to derive valuable additional information, like various wall-motion measurements. In this paper, we present a new efficient method for the functional evaluation of the left ventricle from 3-D echographic sequences. It comprises a segmentation step that is based on the integration of 3-D deformable surfaces and a four-dimensional statistical heart motion model. The segmentation results in an accurate 3-D + time left ventricle discrete representation. Functional descriptors like local wall-motion indexes are automatically derived from this representation. The method has been successfully tested both on electrocardiography-gated and real-time 3-D data. It has proven to be fast, accurate, and robust.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Olivier Gérard, Antoine Collet Billon, Jean-Michel Rouet, Marie Jacob, Maxim Fradkin, Cyril Allouche. 2002. Efficient model-based quantification of left ventricular function in 3-D echocardiography.. https://doi.org/10.1109/tmi.2002.804435

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy: a real-time three-dimensional echocardiographic study.

BACKGROUND: Left ventricular (LV) reconstruction surgery leads to early improvement in LV function in ischemic cardiomyopathy (ICM) patients. This study was designed to evaluate the impact of mitral valve (MV) repair associated with LV reconstruction on LV function 1-year after surgery in ICM patients assessed by real-time 3-dimensional echocardiography (3DE). METHODS AND RESULTS: Sixty ICM patients who underwent the combination surgery (LV reconstruction in 60, MV repair in 30, and revascularization in 52 patients) were studied. Real-time 3DE was performed and LV volumes were obtained at baseline, discharge, 6-month and >or=12-month follow-up. Reduction in end-diastolic volumes (EDV) by 29% and in end-systolic volumes by 38% were demonstrated immediately after surgery and remained at subsequent follow-up (P<0.0001). The LV ejection fraction significantly increased by about 10% at discharge and was maintained >or=12-month (P<0.0001). Although the LV volumes were significantly larger in patients with MV repair before surgery (EDV, 235+/-87 mL versus 193+/-67 mL, P<0.05), they were similar to LV volumes of the patients without MV repair at subsequent follow-ups. However, the EDV increased from 139+/-24 mL to 227+/-79 mL (P<0.01) in 7 patients with recurrent mitral regurgitation (MR). Improvement in New York Heart Association functional class occurred in 81% patients during late follow-up. CONCLUSIONS: Real-time 3DE demonstrates that LV reconstruction provides significant reduction in LV volumes and improvement in LV function which is sustained throughout the 1-year follow-up with 84% cardiac event free survival. If successful, MV repair may prevent LV redilation, while recurrent MR is associated with increased LV volumes.

Echocardiography, Three-Dimensional↗

[Usefulness of intraoperative echocardiography for the management of mitral regurgitation].

Intraoperative transesophageal echocardiography is crucial in the management of patients with mitral regurgitation. In fact, a vast majority mitral insufficiencies may actually be repaired. This kind of surgery require an excellent definition of anatomic lesions and mechanisms of mitral regurgitation in order to optimize the result of the repair. In this field, intraoperative echocardiographic findings are complementary with anatomical findings for the surgeon. Before surgery, intraoperative echography help to describe all valvular lesions and mechanisms of the regurgitation. Three-dimensional echocardiography may be obtained using intraoperative echography and may be useful in mitral valve prolapse to better define the location and size of prolapse and to communicate informations to the surgeon. After repair, echographyallow the control of the result and also of right and left ventricular function. In case of major abnormality such as residual significant mitral regurgitation or important intra-ventricular obstruction, a second procedure may be required. The collaboration between the echographist and the surgeon is crucial to obtain the best results in mitral valve repair. Indications for intraoperative echocardiography are dependent on the experience of the surgeon and the complexity of mitral lesions to repair.

Echocardiography, Three-Dimensional↗

Rapid and accurate left ventricular surface generation from three-dimensional echocardiography by a catalog based method. Rapid LV surface generation by three-dimensional echo.

BACKGROUND: Quantitative analysis from three-dimensional (3D) echocardiography requires accurate reconstruction of left ventricular (LV) surfaces. This currently requires time-consuming manual image tracing. We describe and validate an alternative rapid method of generating LV surfaces. METHODS: A 3D-image set is acquired using transthoracic scanning. Images from five standard echo views are displayed and border points selected where anatomic landmarks are well defined. A LV surface is reconstructed as a convex weighted sum of LVs from a catalog of 80 LVs. The intersections of the surface with the five views are presented on these images. The routine may be rerun until the LV surface matches the images. One LV surface is generated in 3 min +/- 27 s. In 41 studies (19 normal, 15 previous infarction, seven cardiomyopathy) the volumes of the catalog-fit endocardial and epicardial surfaces were compared with volumes from surfaces reconstructed from full manual tracing. RESULTS: Over a wide range of LV volumes and ejection fraction (EF), the catalog-fit results correlated closely to those from manual tracing: end-diastolic volume (194 +/- 99 vs. 204 +/- 110 ml, y = 0.93x, R2 = 0.99, SEE = 19 ml, p < 0.001), end-systolic volume (122 +/- 95 vs. 131 +/- 106 ml, y = 0.92x, R2 = 0.99, SEE = 13 ml, p < 0.001), EF (42 +/- 16 vs. 42 +/- 15%, y = x, R2 = 0.99, SEE = 4%, p < 0.001) and mass (220 +/- 88 vs. 204 +/- 86 g, y = 1.1x, R2 = 0.99, SEE = 24 g, p < 0.001). The endocardial catalog surface was generated from an average of 20 points and three computational runs for both end-diastole and end-systole. CONCLUSIONS: The catalog method of LV reconstruction from 3D-echo provides accurate measurement of volume, EF and mass. The speed of the method is a major advantage.

Echocardiography, Three-Dimensional↗