PubMed Health⌕ Search

PubMed · 12591322

Resistive index cannot predict transplant kidney function.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y-J Chiang, S-H Chu, C-K Chuang, H-W Chen, C-C Chou, Y Chen, C-T Wu. 2003. Resistive index cannot predict transplant kidney function.. https://doi.org/10.1016/s0041-1345(02)03802-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Value of portal hemodynamics and hypersplenism in cirrhosis staging.

AIM: To determine the correlation between portal hemodynamics and spleen function among different grades of cirrhosis and verify its significance in cirrhosis staging. METHODS: The portal and splenic vein hemodynamics and spleen size were investigated by ultrasonography in consecutive 38 cirrhotic patients with cirrhosis (Child's grades A to C) and 20 normal controls. The differences were compared in portal vein diameter and flow velocity between patients with and without ascites and between patients with mild and severe esophageal varices. The correlation between peripheral blood cell counts and Child's grades was also determined. RESULTS: The portal flow velocity and volume were significantly lower in patients with Child's C (12.25+/-1.67 cm/s vs 788.59+/-234 mm/min, respectively) cirrhosis compared to controls (19.55+/-3.28 cm/s vs 1254.03+/-410 mm/min, respectively) and those with Child's A (18.5+/-3.02 cm/s vs 1358.48+/-384 mm/min, respectively) and Child's B (16.0+/-3.89 cm/s vs 1142.23+/-390 mm/min, respectively) cirrhosis. Patients with ascites had much lower portal flow velocity and volume (13.0+/-1.72 cm/s vs 1078+/-533 mm/min) than those without ascites (18.6+/-2.60 cm/s vs 1394+/-354 mm/min). There was no statistical difference between patients with mild and severe esophageal varices. The portal vein diameter was not significantly different among the above groups. There were significant differences in splenic vein diameter, flow velocity and white blood cell count, but not in spleen size, red blood cell and platelet counts among the various grades of cirrhosis. The spleen size was negatively correlated with red blood cell and platelet counts (r = -0.620 and r = -0.8.34, respectively). CONCLUSION: An optimal system that includes parameters representing the portal hemodynamics and spleen function should be proposed for cirrhosis staging.

Blood Flow Velocity↗

Optic nerve cyst associated with optic disk pits.

PURPOSE: To report a case with two optic disk pits which were associated with an optic nerve cyst in the same eye. METHODS: Observational case report. RESULTS: A 47-year-old patient noted visual impairment in the right eye. On examination the best corrected visual acuity in the right eye was 20/80 and in the left eye was 20/20. Biomicroscopy revealed, in the right eye, a very pale optic disk with two optic disk pits without macular elevation. Magnetic resonance imaging (MRI) revealed a well circumscribed 6 x 6-mm(2) round cystic lesion within the right optic nerve sheath adjacent to the temporal aspect of the right optic nerve at its retrobulbar segment, which compressed and displaced the nerve. CONCLUSIONS: In the case of an extremely pale optic disk with congenital pits and visual impairment without macular detachment, radiological examination is indicated in order to exclude the possibility of coexisting optic nerve anomalies.