Tablet surface characterisation by various imaging techniques.

Abstract

The aim of this study was to characterise tablet surfaces using different imaging and roughness analytical techniques including optical microscopy, scanning electron microscopy (SEM), laser profilometry and atomic force microscopy (AFM). The test materials compressed were potassium chloride (KCl) and sodium chloride (NaCl). It was found that all methods used suggested that the KCl tablets were smoother than the NaCl tablets and higher compression pressure made the tablets smoother. Imaging methods like optical microscopy and SEM can give useful information about the roughness of the sample surface, but they do not provide quantitative information about surface roughness. Laser profilometry and AFM on the other hand provide quantitative roughness data from two different scales, laser profilometer from 1 mm and atomic force microscope from 90 microm scale. AFM is a powerful technique but other imaging and roughness measuring methods like SEM, optical microscopy and laser profilometry give valuable additional information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paulus Seitavuopio, Jukka Rantanen, Jouko Yliruusi. 2003-03-26. Tablet surface characterisation by various imaging techniques.. https://doi.org/10.1016/s0378-5173(03)00026-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A method for testing compressive properties of single proteoglycan aggregates.

This study presents a method for direct measurement of the compressive properties of single molecules of proteoglycan aggregate using a state-of-the-art laser tweezers/interferometer system previously developed to test the tensile properties of single molecules. A typical molecule of proteoglycan aggregate showed a highly non-linear resistance to compression after being compressed to about 25% of its original molecule length.

Compressive Strength↗

Immobilization of mercury and zinc in an alkali-activated slag matrix.

The behavior of heavy metals mercury and zinc immobilized in an alkali-activated slag (AAS) matrix has been evaluated using physical property tests, pore structure analysis and XRD, TG-DTG, FTIR and TCLP analysis. Low concentrations (0.5%) of mercury and zinc ions had only a slight affect on compressive strength, pore structure and hydration of AAS matrixes. The addition of 2% Hg ions to the AAS matrix resulted in a reduction in early compressive strength but no negative effects were noticed after 28 days of hydration. Meanwhile, 2% Hg ions can be effectively immobilized in the AAS matrix with the leachate meeting the USEPA TCLP mercury limit. For a 2% Zn-doped AAS matrix, the hydration of the AAS paste was greatly retarded and the zinc concentration in the leachate from this matrix was higher than 5mg/l even at 28 days. Based on these results, we conclude that the physical encapsulation and chemical fixation mechanisms were likely to be responsible for the immobilization of Hg ions in the AAS matrix while only chemical fixation mechanisms were responsible for the immobilization of Zn ions in the AAS matrix.

Compressive Strength↗

Determining the compression behaviour of pharmaceutical powders from the force-distance compression profile.

The force-displacement curves obtained from an eccentric tablet machine were examined in a new way. The tendency of the material for plastic deformation, fragmentation and elasticity is expressed as numerical values, which are comparable between different materials. The dependence of these numerical values on the compression pressure was modelled. The accuracy of the displacement measurement was improved by filtering out noise from the measurement data by a novel method. The plastic deformation of the material near the force maximum of the compression cycle could be seen accurately from this precise displacement data. The elastic deformation of the tablet machine was also defined very precisely from the running machine. Tablets were made with an eccentric tablet machine using fixed lower and upper punch adjustments. This ensured that the speed of the upper punch and the theoretical height of the tablets were the same for all compactions. Therefore, only the properties of the materials determined the differences in the shape of the compression curves. The test materials used were alpha-lactose monohydrate, two grades of microcrystalline cellulose, maize starch and dicalcium phosphate dihydrate. The results showed that the use of accurate displacement measurement is essential in order, to see the small variations in the shape of the force-displacement curve near the force maximum of the compression cycle, and it made it possible to dynamically calibrate the elastic deformation of the eccentric tablet machine during compression. It turned out that the numerical values obtained with the new method described the plastic, brittle and elastic properties of the tested materials satisfactorily in a wide compression pressure range.

Compressive Strength↗