MR imaging at high magnetic fields.

Abstract

Recently, more investigators have been applying higher magnetic field strengths (3-4 Tesla) in research and clinical settings. Higher magnetic field strength is expected to afford higher spatial resolution and/or a decrease in the length of total scan time due to its higher signal intensity. Besides MR signal intensity, however, there are several factors which are magnetic field dependent, thus the same set of imaging parameters at lower magnetic field strengths would provide differences in signal or contrast to noise ratios at 3 T or higher. Therefore, an outcome of the combined effect of all these factors should be considered to estimate the change in usefulness at different magnetic fields. The objective of this article is to illustrate the practical scientific applications, focusing on MR imaging, of higher magnetic field strength. First, we will discuss previous literature and our experiments to demonstrate several changes that lead to a number of practical applications in MR imaging, e.g. in relaxation times, effects of contrast agent, design of RF coils, maintaining a safety profile and in switching magnetic field strength. Second, we discuss what will be required to gain the maximum benefit of high magnetic field when the current magnetic field (< or = 1.5 T) is switched to 3 or 4 T. In addition, we discuss MR microscopy, which is one of the anticipated applications of high magnetic field strength to understand the quantitative estimation of the gain benefit and other considerations to help establish a practically available imaging protocol.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Masaya Takahashi, Hidemasa Uematsu, Hiroto Hatabu. 2003. MR imaging at high magnetic fields.. https://doi.org/10.1016/s0720-048x(02)00331-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protocol for Detecting and Sequencing Chikungunya Virus from Field-Collected Mosquitoes.

Arboviral diseases represent a major public health challenge, especially in tropical regions where environmental conditions may favor the proliferation and spread of mosquito vectors. Thus, early and accurate detection of chikungunya virus (CHIKV) in mosquito populations can be a valuable tool for effective surveillance of circulating variants and for identifying new viral introductions. Given the challenges of detecting arboviruses in field-captured mosquitoes, we describe an integrated workflow for CHIKV molecular detection and whole-genome sequencing. This protocol includes mosquito homogenization using a bead-based mechanical disruptor, RNA extraction using TRIzol reagent with minor modifications, molecular screening using CHIKV-specific RT-qPCR, and whole-genome amplification followed by sequencing on Illumina platforms. Despite the protocol being optimized for individual mosquitoes, it results in high-quality RNA suitable for both entomological surveillance and genomic analysis. As this protocol allows recovery of complete CHIKV genomes from mosquito specimens, it can serve as a basis for genomic epidemiology studies, enabling monitoring of viral diversity and lineage dynamics, and facilitating early detection of emerging variants to support timely and targeted public health interventions in endemic and at-risk regions.

Animals↗

Genomic Profiling of Chromatin State Using CUT&Tag.

Alterations in chromatin state, mediated through histone modifications and the incorporation of histone variants, are fundamental to establishing transcriptional networks and cell identity. Recent advances in low-input epigenome profiling methods, such as CUT&Tag and CUT&RUN, have enabled the study of chromatin states from very limited starting materials. In this chapter, we describe procedures for generating CUT&Tag libraries to profile histone modifications and histone variants in early-developing zebrafish embryos.

Animals↗

Relaxin-2: Shaping the Proteomic Landscape of Skeletal Muscle Physiology, Glucose Trafficking, and Mitochondrial Function in Rat.

Relaxin-2 is a hormone with robust beneficial effects on the heart and blood vessels and potential as a therapy for cardiovascular (CV) disease. Considering the interorgan communication between skeletal muscle and heart, and the relation between muscle quality/composition and CV events, we hypothesize that relaxin-2 may regulate skeletal muscle physiology and metabolism. We aim to evaluate the impact of relaxin-2 on the proteome of skeletal muscle from healthy Sprague-Dawley rats. Animals were treated with 0.4&#x2009;mg/kg/day of serelaxin (recombinant form of human relaxin-2) or vehicle (PBS) for 2&#x2009;weeks employing subcutaneous osmotic minipumps. Skeletal muscle protein identification and quantification were performed by LC-MS/MS using a Data-Independent Acquisition (DIA)-Sequential Window Acquisition of All Theoretical Fragment Ion Spectra (SWATH) method. SWATH/MS quantitative analysis identified that relaxin-2 significantly decreased 95 proteins and significantly increased 32 proteins in rat skeletal muscle when compared to control rats. From these, 34 proteins were associated with muscle function, myogenesis, muscle differentiation and/or regeneration, 20 are mitochondrial proteins (six from the complexes of the electron transport chain), and 10 proteins participate in glucose metabolism. Qualitative data-dependent workflow analysis identified 35 proteins exclusive to the skeletal muscle of the relaxin-2-treated group: eight proteins related to processes of skeletal muscle function (size, ion homeostasis or organization of caveolae structures and cytoskeleton) and myogenesis, and two proteins involved in muscle differentiation. Our work highlighted for the first time the role of relaxin-2 in crucial processes of muscle physiology and energetic metabolism, which could influence several processes involved in myopathy and CV.

Animals↗