PubMed Health⌕ Search

PubMed · 12694844

Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT.

Abstract

PURPOSE: Information concerning the amount and nature of target motion is essential for the determination of internal margin size. However, there are few published reports outlining the motion with heart and aortic pulsation. We introduce a method for three-dimensional radiation treatment planning (3D-RTP) by using electrocardiographically (ECG) gated spiral scanning with a four-section CT system. We describe a new approach to visualize internal organ motion resulting from cardiac motion with ECG gated multidetector row CT. MATERIALS AND METHODS: Five patients with lung or liver tumors were studied with a multidetector row CT system under shallow inspiration breath-holding. With retrospective ECG gating, only data acquired within a predefined interval of the cardiac cycle are used for image reconstruction. All reconstructed image data at diastolic and systolic phases of the cardiac cycle were transferred to the 3D-RTP system. The shift of the internal organs between the cardiac cycles was evaluated. RESULTS: Cardiac contraction influences anterior thorax, pulmonary peripheral vessels, and liver position, in addition to locations near the heart. Apparent movements more than 5 mm between diastolic and systolic phases were observed in the left ventricle, right atrium, and superior vena cava. Two-phase imaging was useful for showing the movement of internal organs during cardiac contraction under breath-holding. CONCLUSIONS: Spatial information using ECG-gated CT has the potential to determine the planning target volume of moving lung and liver tumors more precisely than conventional CT planning.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kazunari Yamada, Toshinori Soejima, Toshiaki Minami, Eisaku Yoden, Yuichi Watanabe, Daisuke Takenaka, Masatake Imai, Takanobu Okayama, Masahiko Fujii, Kazuro Sugimura. 2003-05-01. Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT.. https://doi.org/10.1016/s0360-3016(03)00096-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner.

The first, to our knowledge, miniature dual-axes confocal microscope has been developed, with an outer diameter of 10 mm, for subsurface imaging of biological tissues with 5-7 microm resolution. Depth-resolved en face images are obtained at 30 frames per second, with a field of view of 800 x 100 microm, by employing a two-dimensional scanning microelectromechanical systems mirror. Reflectance and fluorescence images are obtained with a laser source at 785 nm, demonstrating the ability to perform real-time optical biopsy.

Computer Systems↗

Proposal for fulfilling strategic objectives of the U.S. Roadmap for national action on clinical decision support through a service-oriented architecture leveraging HL7 services.

Despite their demonstrated effectiveness, clinical decision support (CDS) systems are not widely used within the U.S. The Roadmap for National Action on Clinical Decision Support, published in June 2006 by the American Medical Informatics Association, identifies six strategic objectives for achieving widespread adoption of effective CDS capabilities. In this manuscript, we propose a Service-Oriented Architecture (SOA) for CDS that facilitates achievement of these six objectives. Within the proposed framework, CDS capabilities are implemented through the orchestration of independent software services whose interfaces are being standardized by Health Level 7 and the Object Management Group through their joint Healthcare Services Specification Project (HSSP). Core services within this framework include the HSSP Decision Support Service, the HSSP Common Terminology Service, and the HSSP Retrieve, Locate, and Update Service. Our experiences, and those of others, indicate that the proposed SOA approach to CDS could enable the widespread adoption of effective CDS within the U.S. health care system.

Computer Systems↗

Imaging tumour motion for radiotherapy planning using MRI.

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.

Computer Systems↗