PubMed Health⌕ Search

PubMed · 12765390

Source motion mitigation for adaptive matched field processing.

Abstract

Application of adaptive matched field processing to the problem of detecting quiet targets in shallow water is complicated by source motion, both the motion of the target and the motion of discrete interferers. Target motion causes spreading of the target peak, thereby reducing output signal power. Interferer motion increases the dimensionality of the interference subspace, reducing adaptive interference suppression. This paper presents three techniques that mitigate source motion problems in adaptive matched field processing. The first involves rank reduction, which enables adaptive weight computation over short observation intervals where motion effects are less pronounced. The other two techniques specifically compensate for source motion. Explicit target motion compensation reduces target motion mismatch by focusing snapshots according to a target velocity hypothesis. And time-varying interference filtering places time-varying nulls on moving interferers not otherwise suppressed by adaptive weights. The three techniques are applied to volumetric array data from the Santa Barbara Channel Experiment and are shown to improve output signal-to-background-plus-noise ratio by more than 3 dB over the standard minimum-variance, distortionless response adaptive beam-former. Application of the techniques in some cases proves to be the difference between detecting and not detecting the target.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lisa M Zurk, Nigel Lee, James Ward. 2003. Source motion mitigation for adaptive matched field processing.. https://doi.org/10.1121/1.1561817

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sensitivity of the acoustic waveguide biosensor to protein binding as a function of the waveguide properties.

The aim of this work is to study the effect of operating frequency, piezoelectric substrate and waveguide layer thickness on the sensitivity of the acoustic waveguide sensor during the specific binding of an antibody by a protein. Shear horizontal (SH) wave devices consisting of (a) a LiTaO3 substrate operating at 104 MHz, (b) a quartz substrate operating at 108 MHz and (c) a quartz substrate operating at 155 MHz were coated with a photoresist polymer layer in order to produce acoustic waveguide devices supporting a Love wave. The effect of the thickness of the polymer layer on the Love wave was assessed by measuring the amplitude and phase of the wave before and after coating. The sensitivity of the above three biosensors was compared during the detection of the specific binding of different concentrations of Immunoglobulin G in the range of 0.7-667 nM to a protein A modified surface. Results indicate that the thickness of the polymer guiding layer is critical for obtaining the maximum sensitivity for a given geometry but a trade-off has to be made between the theoretically determined optimum thickness for waveguiding and the device insertion loss. It was also found that increasing the frequency of operation results in a further increase in the device sensitivity to protein detection.

Acoustics↗

Study of the diffusion of some emulsions in the human skin by pulsed photoacoustic spectroscopy.

We previously used pulsed photoacoustic spectroscopy (PPAS) to quantify sunscreen diffusion into human skin, and suggested a methodology to evaluate the time and the depth diffusion profile. These results were obtained by the analysis of the photoacoustic maximum response signal Pmax decrease, the time delay tmax and the Fourier transform representation of the photoacoustic signal. In this study we present the results obtained for diffusion of four typical emulsions used in sunscreen compositions that show, for the first time, a particular behaviour for one of these emulsions due to a chemical reaction inside the skin during the diffusion process. This result provides a particularly interesting technique through the PPAS, to evaluate in situ the eventual chemical reactions that can occur during drug diffusion into human skin.

Acoustics↗