Liquid level sensor using ultrasonic Lamb waves.

Abstract

This paper describes a novel, noninvasive method for measurement of liquid level in closed metal tanks that are under high pressure. It is based on the use of ultrasonic Lamb waves propagating along the tank wall. Contact with liquid substantially changes the characteristics of these waves and this can be used as an indicator of liquid presence. Theoretical analysis shows that the symmetric and antisymmetric Lamb wave modes, both fundamental and higher order, are sensitive to presence of the liquid. The optimal wave frequency depends on the thickness of the tank wall and wall material. A prototype level sensor based on this principle has been developed. It uses two pairs of wedge transducers to generate and detect Lamb waves propagating along the circumference of the gas tank. An operating frequency of 100 kHz is found to be optimal for use with tanks having a wall thickness of 30-50 mm. Prototype sensors developed under this program have been used successfully in oil fields in the far northern region of Russia.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V E Sakharov, S A Kuznetsov, B D Zaitsev, I E Kuznetsova, S G Joshi. 2003. Liquid level sensor using ultrasonic Lamb waves.. https://doi.org/10.1016/s0041-624x(02)00459-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multiaxial fatigue behavior of conventional and highly crosslinked UHMWPE during cyclic small punch testing.

Previous observations of reduced uniaxial elongation, fracture resistance, and crack propagation resistance of highly crosslinked ultrahigh molecular weight polyethylene (UHMWPE) have contributed to concern that the technology may not be appropriate for systems undergoing cyclic fatigue loading. Using a "total life" approach, we examined the influence of radiation crosslinking on the fatigue response of UHMWPE under cyclic loading via the small punch test. Our goal in this study was to evaluate the suitability of the small punch test for conducting miniature-specimen, cyclic loading, and fatigue experiments of conventional and highly crosslinked UHMWPE. We subjected four types of conventional and highly crosslinked UHMWPE to cyclic loading at 200 N/s and at body temperature in a small punch test apparatus. After failure, the fracture surfaces were characterized with the use of field emission scanning electron microscopy to evaluate the fatigue mechanisms. Cyclic small punch testing under load control was found to be an effective and repeatable method for relative assessment of the fatigue resistance of conventional and highly crosslinked UHMWPE specimens under multiaxial loading conditions. For each of the four conventional and highly crosslinked UHMWPE materials evaluated in this study, fatigue failures were consistently produced according to a power law relationship in the low cycle regimen, corresponding to failures below 10000 cycles. The fatigue failures were all found to be consistent with a single source of initiation and propagation to failure. Our long-term goal in this research is to develop miniature-specimen fatigue testing techniques for characterization of retrieved UHMWPE inserts.

Materials Testing↗

Surface modification of an experimental silicone rubber maxillofacial material to improve wettability.

OBJECTIVES: Good wettability of maxillofacial prosthetic materials is important so that a lubricating layer is formed with supporting tissues thus reducing patient discomfort. The purpose of the study was to surface modify an experimental silicone rubber material in order to improve wettability. METHODS: Samples of experimental silicone rubber were surface modified by first argon plasma treatment followed by chemisorption of ethyleneoxy functional silanes. These were compared with the same silicone rubber which had ethyleneoxy functional surfactants incorporated into the polymer matrix. In all cases contact angles, tear strength and water uptake were measured. RESULTS: Surface modified materials had comparable contact angles to surfactant modified silicone rubber all being significantly lower than the unmodified material. Surface modified materials, however, had a significantly higher tear strength and lower water uptake in comparison to surfactant modified materials. CONCLUSIONS: Argon plasma treatment followed by chemisorption of ethyleneoxy functional silanes proved an effective way of improving the wettability of an experimental silicone rubber maxillofacial prosthetic material without altering bulk properties.

Materials Testing↗