A new acceleration driven pacemaker: rate modulation versus normal sinus rhythm--comparison during treadmill exercise.

Abstract

The pacing rate response of a new acceleration driven pulse generator (SWING 100, SORIN BIOMEDICA) was compared with simultaneous normal sinus rhythm (NSR) during two different treadmill exercises. This pacemaker has a gravitational acceleration sensor able to discriminate between physical activities and vibrations. Six healthy volunteers (three male, three female; aged 21.7 +/- 4.3 years), with the pacemaker strapped to their right infraclavicular area, performed each test three times with different rise response curve (RRC) each time: fast, normal, and slow. The fall response curve used was the same as the rising one during each test. Pacing rates were recorded using the VEGA analyzer (SORIN BIOMEDICA) and compared with simultaneous NSR recorded by a 7-channel ECG recorder (MINGOGRAF 7, SIEMENS). During all tests immediate (within seconds) rapid increase in pacemaker rate was seen up to about 60 seconds, then a slower increase followed thereafter. The mean correlation between pacing rates and NSR during the Bruce tests were 0.7941 +/- 0.10, 0.8562 +/- 0.14, and 0.8292 +/- 0.07; during the discontinuous tests 0.7292 +/- 0.16, 0.7233 +/- 0.10, and 0.7480 +/- 0.11 for fast, normal, and slow RRC, respectively. Each 30 seconds, nonsignificant differences were present between pacing rate and NSR during all the discontinuous tests; similar responses were observed only during the first two stages of Bruce tests after which NSR was significantly higher than pacemaker rates. The speed of rise to upper rate was the main difference between the different programs (fast, normal, and slow). The discontinuous tests showed that the pacemaker responds more to speed than to grade.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A I Soussou, M G Helmy, R R Guindy, E M Greco. 1992. A new acceleration driven pacemaker: rate modulation versus normal sinus rhythm--comparison during treadmill exercise.. https://doi.org/10.1111/j.1540-8159.1992.tb02972.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Does the type of prehension influence the kinematics of reaching?

Kinematic studies have indicated that when a subject reaches to grasp an object, the movement consists of two primary components: (a) a transport phase whereby the hand is brought towards the object and (b) a grip phase whereby the hand changes shape in anticipation of the grasp. Using a visual perturbation paradigm, we investigated the effect of different grip component strategies upon the transport phase. The distal strategy was determined by the size of the object to be grasped: for the small object (1.5 cm o.d.) subjects naturally adopted a precision grip between the index finger and thumb; for the large object (6 cm o.d.) subjects used a whole hand prehensile grip. During 20% of the reaching trials the perturbation was introduced by unexpectedly changing the object size. The results showed that corrections to the distal program in response to the perturbation were preceded by changes in the deceleration phase of the proximal component. The data supported previous findings of two visuo-motor channels for this prehensile movement but indicated that when unanticipated shifts of only the distal program are required, both channels show modifications.

Acceleration