PubMed Health⌕ Search

PubMed · 12857708

Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study.

Abstract

The aim of this study was to evaluate the potential for radiation dose reduction by using other beam qualities in full-field digital mammography (FFDM) compared with screen-film mammography (SFM). FFDM was performed using an amorphous silicon detector with a caesium iodide scintillator layer (Senographe 2000D, GE, Milwaukee, USA). SFM was performed using a state-of-the-art conventional system (Senographe DMR, GE, Milwaukee, USA) with a dedicated screen-film combination. An anthropomorphic breast phantom with superimposed microcalcifications (50-200 microm) was used to evaluate the detectability of microcalcifications. Contact mammograms and magnification views (m=1.8) performed with both the digital and the screen-film system were compared. Images were exposed automatically. Molybdenum/Molybdenum (Mo/Mo) anode-filter combination, 28 kVp and 63 mAs were selected by the automatic optimization of parameters (AOP) of the conventional system. This exposure protocol (protocol A) was also used as baseline for the digital system. Dose reduction in digital mammography was achieved by using protocol B with Mo/Rh and 31 kVp and protocol C with Rh/Rh and 32 kVp. The detectability of microcalcifications was assessed by 3 experienced readers with a confidence level ranging from 1 to 5. A receiver operating characteristic (ROC) analysis was performed. In protocol A the area under the ROC-curve (A(z)) for contact views performed by the screen-film system was 0.64 and for those performed with the FFDM system 0.68. The A(z) values were 0.74 in protocol B and 0.65 in protocol C for the digital system. For the conventional and digital magnification views A(z) values were 0.71 and 0.79, respectively. For protocol B the A(z) value was 0.81 and for protocol C it was 0.76. There is no statistically significant difference in the A(z) values for the different protocols in digital mammography and no significant difference from the screen-film system. A potential for dose reduction by using other beam qualities seems to be possible with this digital system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Obenauer, K-P Hermann, E Grabbe. 2003. Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study.. https://doi.org/10.1259/bjr%2F67597156

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plasma levels of active ghrelin until 8 weeks after birth in preterm infants: relationship with anthropometric and biochemical measures.

This study investigated the relationship between plasma levels of ghrelin and postnatal growth in preterm infants. The levels of active ghrelin in cord blood and in plasma in 25 very low birthweight (VLBW) infants were measured. The results indicate that the levels of circulating active ghrelin markedly increases after birth in VLBW infants, and suggest that the increased levels of ghrelin reflects the maturation of ghrelin production in the stomach and an increased physiological need for ghrelin.

Anthropometry↗

A high-resolution anthropomorphic voxel-based tomographic phantom for proton therapy of the eye.

Proton therapy is increasingly used in medical treatments for cancer patients due to the sharp dose conformity offered by the characteristic Bragg peak. Proton beam interactions with the eye will be simulated using the MCNPX Monte Carlo code and available nuclear cross-section data to calculate the dose distribution in the eye gel and surrounding organs. A high-resolution eye model will be employed using a 3D geometrical voxel-based anthropomorphic head phantom obtained from the Visible Human Project (female data). Manual segmentation of the eye, carried out by the Medical Physics group at the University of Surrey resulted in 15 identified structures. This work emphasizes the use of a realistic phantom for accurately predicting dose deposition by protons.

Anthropometry↗

Phenotypic, maximum genetic, and special environmental variability in prehistoric human populations.

The phenotypic variance (V(P)) may be divided into the genetic variance (V(G)), the general environmental variance (V(Eg)), and the special environmental variance (V(Es)). The latter is estimated through repeatability calculation (b). This value is considered the upper limit of heritability and represents maximum genetic variance proportion (V(Gm) = V(G) + V(Eg)) in relation to V(P) (b = (V(G) + V(Eg))/V(P)). This process allows an improved determination of biological relationships among groups from estimators maximizing the genetic information of quantitative characters. Two hundred and thirty-seven individuals inhabiting the northern coast of Chile for 4,000 years were taken as a sample. Measurement was made of six metric characters at both sides of the cranium. Special environmental values (es) were obtained by regression. The difference between these values and the phenotypic values (p) consists in the genetic values plus the general environmental values (g + eg). A mean b value of 0.83 indicated that V(Es) represents 17% of V(P). The results showed: 1) high stability of the maximum genetic variance in time and space, 2) high correlation between the biological relationships model, the phenotypic model, and the maximum genetic model, and 3) random distribution of the nongenetic variation, as expected from the quantitative genetics theory. These results support the use of phenotypic data for the interpretation of the evolution history of prehistoric populations.

Anthropometry↗