PubMed Health⌕ Search

PubMed · 1293913

[Leprosy serology: current status and perspectives].

Abstract

The different serological tests used for leprosy are firstly the methods for the detection of antibodies (anti-PGL1, 35kD, 36kD, LAM), and secondly, the tests to detect the PGL1 antigen from the serum or urine. The antibody detection tests have a good but insufficient specificity for the diagnosis of leprosy patients and their sensitivity is generally high for the multibacillary patients but low for the paucibacillary patients. Their positive predictive value for the diagnosis of patients in a population are very low: 2.1% for the anti-PGL1 ELISA when the prevalence is 1/1000. For the early diagnosis of patients and the follow up of high risk populations, these tests are not cost effective: the number of patients detected in these populations is 10 fold lower than in the general population and the relative risks for developing the disease are not different among seropositive and among seronegative groups. In treated multibacillary patients, the IgM anti-PGL1 level decreases in correlation with the decrease of the bacillary index. For the diagnosis of M. leprae infection in a population, there was no correlation between the anti-PGL1 seroprevalence and the prevalence of the disease. Concerning the PGL1 antigen detection tests, they are specific and sensitive for the diagnosis of multibacillary patients but they cannot be used in routine for technical reasons. In conclusion and to date, the usefulness of serological tests in a leprosy control programme is quite questionable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Chanteau, J L Cartel, J Roux. 1992. [Leprosy serology: current status and perspectives].. https://pubmed.ncbi.nlm.nih.gov/1293913/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Recombinant truncated nucleocapsid protein as antigen in a novel immunoglobulin M capture enzyme-linked immunosorbent assay for diagnosis of severe acute respiratory syndrome coronavirus infection.

We report the development of an immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) for severe acute respiratory syndrome coronavirus (SARS-CoV) by using recombinant truncated SARS-CoV nucleocapsid protein as the antigen. The newly developed MAC-ELISA had a specificity and sensitivity of 100% as evaluated by using sera from healthy volunteers and patients with laboratory-confirmed SARS. Using serial serum samples collected from SARS patients, the times to seroconversion were determined by IgM antibody detection after SARS-CoV infection. The median time to seroconversion detection was 8 days (range, 5 to 17 days) after disease onset, and the seroconversion rates after the onset of illness were 33% by the first week, 97% by the second week, and 100% by the third week. Compared with the results of our previous report on the detection of IgG, the median seroconversion time by IgM detection was 3 days earlier and the seroconversion rate by the second week after the illness for IgM was significantly higher than by IgG assay. Our results indicating that the IgM response appears earlier than IgG after SARS-CoV infection in consistent with those for other pathogens. Our newly developed MAC-ELISA system offers a new alternative for the confirmation of SARS-CoV infection.

Enzyme-Linked Immunosorbent Assay↗

Perfusion with lipopolysaccharide differently affects the secretion of tumor necrosis factor-alpha and interleukin-6 by term and preterm human placenta.

This study has compared the functional capacity of term and preterm placentas in terms of production of pro-inflammatory cytokines in a perfusion system reflecting their ability to react to inflammatory agents, such as lipopolysaccharide (LPS), mimicking the situation of chorioamnionitis. We have demonstrated that term placentas secrete higher levels of tumor necrosis factor (TNF)-alpha compared with preterm placentas. Moreover, TNF-alpha secretion was significantly higher after exposure to LPS in the maternal and fetal sides of term placentas. In contrast, in preterm placentas, only the fetal side responded with a significant increase in secretion of TNF-alpha after exposure to LPS. The maternal side of term placentas secreted significantly higher amounts of interleukin (IL)-6 compared with preterm placentas. Exposure to LPS significantly decreased IL-6 secretion from the maternal side in both term and preterm placentas. Moreover, the fetal side of term placentas secreted significantly lower amounts of IL-6 compared with preterm placentas. In summary, this study has indicated that term and preterm placental tissues have a differing responsiveness to LPS stimulation, with term placentas disposed to a higher TNF-alpha:IL-6 ratio. Release of cytokines into fetal circulation is less than into the maternal side. However, TNF-alpha is released into fetal circulation after LPS stimulation and this may be relevant to the etiology of chorioamnionitis.

Enzyme-Linked Immunosorbent Assay↗