PubMed Health⌕ Search

PubMed · 12954003

CTA and MRA: visualization without catheterization.

Abstract

The ideal modality for vascular imaging would be noninvasive and inexpensive. A volumetric acquisition would permit visualization of vessels from arbitrary angles. High contrast between the vessel lumen and background tissue would be coupled with excellent spatial resolution allowing accurate depiction of small vessels. Characterization of the constituent components of the vessel wall would be possible. High temporal resolution would both freeze the motion of fast moving vessels and show the direction and speed of blood flow. Finally, the modality would expose the patient to a minimal amount of ionizing radiation or potentially toxic contrast agents. Diagnostic conventional catheter angiography offers unsurpassed spatial and temporal resolution. However, catheter angiography is an interventional procedure, exposes the patient to both ionizing radiation and iodinated contrast, and does not depict the vessel wall. Additionally, view angles are chosen before the administration of contrast and may not demonstrate certain lesions. These limitations have driven the development of both computed tomography angiography (CTA) and magnetic resonance angiography (MRA). Both of these modalities rapidly acquire volumetric data sets, which can then be evaluated slice by slice or by more advanced volumetric rendering techniques. CTA and MRA are minimally invasive and less costly than angiography. While CTA and MRA cannot compete with the spatial or temporal resolution of conventional angiography, present technology has proven clinical efficacy in a wide range of applications. The principles behind CTA and MRA and their comparative strengths and weaknesses will be discussed. The different volumetric rendering techniques will be reviewed. Finally, recent advances that will likely further improve these modalities will be summarized.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Douglas Green, Dennis Parker. 2003. CTA and MRA: visualization without catheterization.. https://doi.org/10.1016/s0887-2171(03)90011-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients: Physiologic Investigation for Transplant Arteriopathy (PITA Study).

BACKGROUND: The utility of measuring fractional flow reserve (FFR) to assess cardiac transplant arteriopathy has not been evaluated. Measuring coronary flow reserve (CFR) as well as FFR could add information about the microcirculation, but until recently, this has required two coronary wires. We evaluated a new method for simultaneously measuring FFR and CFR with a single wire to investigate transplant arteriopathy. METHODS AND RESULTS: In 53 cases of asymptomatic cardiac transplant recipients without angiographically significant coronary disease, FFR and thermodilution-derived CFR (CFRthermo) were measured simultaneously with the same coronary pressure wire in the left anterior descending artery and compared with volumetric intravascular ultrasound (IVUS) imaging. The average FFR was 0.88+/-0.07; in 75% of cases, the FFR was less than the normal threshold of 0.94; and in 15% of cases, the FFR was < or =0.80, the upper boundary of the gray zone of the ischemic threshold. There was a significant inverse correlation between FFR and IVUS-derived measures of plaque burden, including percent plaque volume (r=0.55, P<0.0001). The average CFRthermo was 2.5+/-1.2; in 47% of cases, CFRthermo was < or =2.0. In 14%, the FFR was normal (> or =0.94) and the CFR was abnormal (<2.0), suggesting predominant microcirculatory dysfunction. CONCLUSIONS: FFR correlates with IVUS findings and is abnormal in a significant proportion of asymptomatic cardiac transplant patients with normal angiograms. Simultaneous measurement of CFR with the same pressure wire, with the use of a novel coronary thermodilution technique, is feasible and adds information to the physiological evaluation of these patients.

Angiography↗

Collagenase plaque digestion for facilitating guide wire crossing in chronic total occlusions.

BACKGROUND: Chronic total occlusions (CTOs) are associated with significant angina, impaired left ventricular function, and worse long-term outcomes. Percutaneous coronary interventions in CTO are unsuccessful in up to 50% of cases, primarily because of inability to cross the lesion with a guide wire. Collagen is the predominant component of the atherosclerotic plaque. The objective of this study was to determine the efficacy and toxicity of local delivery of a collagen-degrading enzyme to facilitate guide wire crossing in CTO. METHODS AND RESULTS: Type IA collagenase (100 or 450 microg) or placebo was locally administered to 45 CTOs in a rabbit femoral artery model. Mean occlusion duration was 16+/-5 weeks. Attempts to cross the CTO (mean length, 28+/-9 mm) with conventional guide wires were assessed at 72 hours after treatment. An additional 3 arteries per group were assessed for collagenase effects at 24 hours after treatment. Successful guide wire crossings were significantly higher in collagenase-treated arteries (13 of 21, 62%) than in placebo-treated arteries (7 of 24, 29%) (P=0.028). No adverse effects on arterial structure were observed in collagenase-treated arteries. At 24 hours, collagenase-treated arteries demonstrated increased collagenase protein, gelatinase activity, and collagen fragments. CONCLUSIONS: Local delivery of collagenase can safely facilitate guide wire crossing of CTO. This novel approach could lead to higher percutaneous coronary intervention success rates in CTO.

Angiography↗

Principles and applications of balanced SSFP techniques.

During the past 5 years balanced steady-state free precession (SSFP) has become increasingly important for diagnostic and functional imaging. Balanced SSFP is characterized by two unique features: it offers a very high signal-to noise ratio and a T2/T1-weighted image contrast. This article focuses on the physical principles, on the signal formation, and on the resulting properties of balanced SSFP. Mechanisms for contrast modification, recent clinical application, and potential extensions of this technique are discussed.

Angiography↗