Analysis of body segment parameter differences between four human populations and the estimation errors of four popular mathematical models.

Abstract

Calculating the kinetics of motion using inverse or forward dynamics methods requires the use of accurate body segment inertial parameters. The methods available for calculating these body segment parameters (BSPs) have several limitations and a main concern is the applicability of predictive equations to several different populations. This study examined the differences in BSPs between 4 human populations using dual energy x-ray absorptiometry (DEXA), developed linear regression equations to predict mass, center of mass location (CM) and radius of gyration (K) in the frontal plane on 5 body segments and examined the errors produced by using several BSP sources in the literature. Significant population differences were seen in all segments for all populations and all BSPs except hand mass, indicating that population specific BSP predictors are needed. The linear regression equations developed performed best overall when compared to the other sources, yet no one set of predictors performed best for all segments, populations or BSPs. Large errors were seen with all models which were attributed to large individual differences within groups. Equations which account for these differences, including measurements of limb circumferences and breadths may provide better estimations. Geometric models use these parameters, however the models examined in this study did not perform well, possibly due to the assumption of constant density or the use of an overly simple shape. Creating solids which account for density changes or which mimic the mass distribution characteristics of the segment may solve this problem. Otherwise, regression equations specific for populations according to age, gender, race, and morphology may be required to provide accurate estimations of BSPs for use in kinetic equations of motion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jennifer L Durkin, James J Dowling. 2003. Analysis of body segment parameter differences between four human populations and the estimation errors of four popular mathematical models.. https://doi.org/10.1115/1.1590359

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗