PubMed Health⌕ Search

PubMed · 13435395

Fluoride osteosclerosis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C A STEVENSON, A R WATSON. 1957. Fluoride osteosclerosis.. https://pubmed.ncbi.nlm.nih.gov/13435395/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel methods of measuring single scan dose profiles and cumulative dose in CT.

Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained within the chamber length may not be valid even for thin slices. We have measured the SSDPs for several slice widths on two CT scanners using a PTW diamond detector placed in a 300 mm x 200 mm x 300 mm water-equivalent plastic phantom. One SSDP was also measured using lithium fluoride (LiF) TLDs and an IC-10 small volume ion chamber, verifying the general shape of the SSDP measured using the diamond detector. Standard cylindrical PMMA CT phantoms (140 mm length) were also used to qualitatively study the effects of phantom shape, length, and composition on the measured SSDP. The SSDPs measured with the diamond detector in the water-equivalent phantom were numerically integrated to calculate the relative accumulated dose D(L)(0)calc at the center of various scan lengths L. D(L)(0)calc reached an equilibrium value for L > 300 mm, suggesting the need for phantoms longer than standard CT dose phantoms. We have also measured the absolute accumulated dose using an IC-10 small volume ion chamber, D(L)(0)SV, at three points in the phantom cross section for several beamwidths and scan lengths. For one CT system, these measurements were made in both axial and helical scanning modes. The absolute CTDI100, measured with a 102 mm active length pencil chamber, were within 4% of D(L)(0)SV measured with the small volume ion chamber for L approximately 100 mm suggesting that nonpencil chambers can be successfully used for CT dosimetry. For nominal beam widths ranging from 3 to 20 mm and for L approximately 250 mm, D(L)(0)SV values at the center of the water-equivalent phantom's elliptic cross section were approximately 25%-30% higher than the measured CTDI100. For small beamwidths, the difference in D(L)(0)SV for L approximately 250 mm and L approximately 14 x beamwidth (CTDI14nT) reached up to 50%. Peripheral point doses at 70 mm depth along the major axis of the phantom for L approximately 250 mm were up to 22% higher than for L approximately 100 mm. The differences between CTDI100 and D(L)(0)SV for L approximately 250 mm were in good agreement with the predictions made from the numerical integration of the measured SSDPs. Due to the considerable dose measured beyond the length of standard CT phantoms, CT dosimetry for longer body scan series should be performed in longer phantoms. Measurements could be made as we have shown, using a small volume chamber translating through the beam using multiple scans.

Fluorides↗

Removal of fluoride from water through ion exchange by mesoporous Ti oxohydroxide.

In our previous study, we found that Ti(OH)(4) exhibited fluoride ion exchange properties. In order to improve the ion exchange capacity, mesoporous Ti oxohydroxide (TiOx(OH)y) had been prepared by using dodecylamine as template. Zirconia and silica had been introduced into the mesoporous Ti oxohydroxide to enhance the ion exchange capacity. The mesoporous structure and the morphology of the mesoporous materials obtained were confirmed using XRD and SEM, respectively. A fluoride ion exchange study was done on each sample. Results showed that mesoporous Ti oxohydroxide containing zirconia exhibited the highest fluoride ion exchange capacity, as it has the smallest particle size, with high uniformity among the mesoporous materials prepared.

Fluorides↗

Vibrational spectra of trimethylsilanol. The problem of the assignment of the SiOH group frequencies.

The assignment of the SiOH group vibrations of trimethylsilanol, which is still controversial, is proposed. This assignment is based on theoretical B3LYP force field scaled using the constants of the (CH3)3Si group optimized to fit experimental vibrational frequencies of (CH3)3SiF and (CD3)3SiF molecules as well as the OH stretching scale factor from methanol. The ab initio force field defined in this way gives a good agreement of the theoretical vibrational frequencies of trimethylsilanol with the positions of IR and Raman bands observed in the gas phase. This force field predicts the greatest contribution of the delta SiOH coordinates to the vibration with frequency of 804 cm(-1). The elimination of the coupling of the SiOH deformation with methyl rocking modes by the normal coordinate treatment of (CD3)3SiOH gives 832 cm(-1) for silanol deformation which is in a good agreement with the 834 cm(-1) value proposed earlier for the bending mode of free silanol groups. The geometry and force field of the open chain H3SiOH trimer is computed to model the change of the delta SiOH frequencies upon formation of the hydrogen-bonded polymers. This model predicts a significant shift of SiOH bending frequencies to the 1000-1200 cm(-1) range while those of SiOD to the 800-850 cm(-1) range. These predictions allow us to ascribe the 1087 cm(-1) band observed in the IR spectrum of crystalline (CH3)3SiOH and the Raman 775 cm(-1) band of the liquid (CH3)3SiOD to deformations of the hydrogen-bonded silanol groups.

Fluorides↗