PubMed Health⌕ Search

PubMed · 13679489

A timesaving method to create a fixed puncture route for the buttonhole technique.

Abstract

BACKGROUND: Up to now, for a successful buttonhole puncture of the vascular access vessel, the fistula should be punctured by the same experienced medical staff for 2-3 months, using sharp needles, until a fixed puncture route is established. METHODS: We developed a timesaving method to create the fixed puncture route for the buttonhole technique. In this method, after the usual haemodialysis (HD), a newly developed thumbtack-shaped polycarbonate peg is thrust toward the access vessel along the same path as the puncture needle that has just been removed. Then, at the beginning of the next HD, the peg is removed and a dull puncture needle is inserted along the track already formed by the peg left in place. These steps are repeated at each HD session for 14 days. Thereafter, the vascular access is achieved at HD sessions by inserting a dull puncture needle through the established puncture route. RESULTS: This buttonhole puncture approach was used in 37 patients for 3 months. While the polycarbonate peg was in place, patients experienced no restrictions in their normal activities of daily living, except during bathing and showering. As for puncture pain, no patient found the pain of the buttonhole technique to be greater than that of the conventional puncture technique. Moreover, no significant bleeding was noted during HD. With this buttonhole puncture approach, only one patient had enough erythema at the puncture site to suggest possible infection. After HD, the time for bleeding to stop was <10 min in 95% of patients. CONCLUSION: This study showed the new timesaving method for creating a buttonhole to be safe and useful.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shigeki Toma, Takahiro Shinzato, Hiroyoshi Fukui, Shigeru Nakai, Masamiki Miwa, Ichiro Takai, Kenji Maeda. 2003. A timesaving method to create a fixed puncture route for the buttonhole technique.. https://doi.org/10.1093/ndt%2Fgfg321

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The role of surgery in the management of septic shock--extra-abdominal causes of sepsis.

Septic shock is a severe inflammatory response to one or more pathogenic micro-organisms. When a person's immune response is excessively intense, a cascade of phenomena may be activated that ultimately is harmful. Appropriate management of septic shock may include surgical intervention to remove or neutralize the septic focus in an effort to treat the inflammatory response cascade. This is the first of two articles presenting current information on the role of surgery in the management of a patient with septic shock. This article describes extra-abdominal sources of sepsis.

Catheters, Indwelling↗

Compatibility of electrolytically produced sodium hypochlorite solutions on long- term implanted dialysis catheters.

More than 20% of the world's population use a catheter for dialysis, despite guidelines limiting their use. Although the structure and design of the catheters differ by manufacturer, the material used in central venous catheters and peritoneal dialysis catheters are the same across manufacturers. Given the long-term use of these catheters in the dialysis population, the good compatibility of the antiseptics and disinfectants used on the catheters is imperative to prevent failure and cracking of the catheter material. Tensile strengths of commercially available catheters were measured after exposure to commonly used disinfectants. The tensile strength was then compared between the catheters by analyzing the displacement vs. force (N) curves produced during the evaluation. A total of 44 catheter lumens were evaluated. The electrolytically produced sodium hypochlorite solution, Alcavis 50/ExSept Plus, was the only solution shown to be compatible with all three catheter materials resulting in a deviation of less than 10% for each of the different catheter types. Electrolytically produced sodium hypochlorite solutions were the only solutions in this study that did not alter the physical properties of any of the catheters after long-term exposure.

Catheters, Indwelling↗