Fetal red cell staining: method evaluation.

Abstract

Acid elution methods have been extensively used for the identification of fetal red cells in pregnant women with fetomaternal hemorrhage. A number of methods have been described: Kleihauer-Betke, Boehringer Mannheim, Fetaldex, Nierhaus-Betke modification and Sanguansermsri amido black B. A comparative evaluation of these methods was performed in this study. The technique of Sanguansermsri using amido black B was found to be more advantageous than the others in terms of simplicity, accuracy, precision and time taken.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Apibal, A Hongyantarachi, P Chiewsilp, S Fucharoen. 1992. Fetal red cell staining: method evaluation.. https://pubmed.ncbi.nlm.nih.gov/1402473/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of plateletpheresis using Cobe Spectra System and Fresenius AS 104.

To evaluate separation efficiency and concentrate purity, each of 50 donors underwent platelet (PLT) collection on both the Cobe Spectra and Fresenius AS 104 with the constancy of processed blood volume, ACD/blood ratio 1:10 and a blood flow of 50 ml/min. For the Fresenius AS 104 two protocols - V 4.11 and V 4.4 - were evaluated. Both systems provided high quality PLT collection: PLT yield 3.91 +/- 0.74 x 10(11) (Cobe); 4.16 +/- 1.12 x 10(11) (V 4.11); 4.66 +/- 0.89 x 10(11) (V 4.4). The mean cell contamination was low with all procedures, resulting in less WBC contamination with the Fresenius AS 104, whereby the higher efficiency obtained by the protocol version V 4.4 correlated with an increased of WBC contamination.

Erythrocyte Count

The basics of blood cell counter.

The time has come when a traditional hematologist of a developing country needs to change his frame of mind from time consuming, error prone, not so precise manual methodologies to economical, safe and precise automated procedures. More important is his role as a guide and teacher for his juniors who are exposed to automated laboratories from the beginning of their residency. At this juncture, one needs to be thorough with the principles of instrumentation, different models available, their merits and demerits and how and where these fit with the requirements of the laboratory. The haematologists also must be aware that automation has its own problems, limitations, disadvantages and interfering elements. The article discusses the present state of art.

Erythrocyte Count

Multivariate statistical modeling: alternative approach to test evaluation, applied to counting reticulocytes by flow cytometry.

We present a statistical path analysis model for the evaluation of two tests in the absence of a "gold standard" method. This model is applied to the evaluation of flow-cytometric and visual reticulocyte counting by using as the comparison method a combination of three hematological measurements: hemoglobin concentration (HGB), mean cellular volume (MCV), and erythrocyte density width (EDW). We assumed that, in general, a higher reticulocyte count is associated with a lower HGB value and with greater values for MCV and EDW. Applying this assumption and the statistical model, we demonstrated that flow cytometry was superior to visual reticulocyte counting in the low-value range studied. The path analysis model is potentially applicable in other cases where two tests are to be compared, and when no gold standard is available.

Erythrocyte Count