PubMed Health⌕ Search

PubMed · 14232383

RADIOLOGICAL NOTES; CASE NO. 244.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C BLOCH, H M PECK. RADIOLOGICAL NOTES; CASE NO. 244.. https://pubmed.ncbi.nlm.nih.gov/14232383/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Vascular calcification in ex vivo carotid specimens: precision and accuracy of measurements with multi-detector row CT.

PURPOSE: To test the accuracy and precision of multi-detector row computed tomography (CT)-derived measurements of vascular calcification in ex vivo human carotid endarterectomy (CEA) specimens. MATERIALS AND METHODS: Sixteen ex vivo CEA specimens were imaged with multi-detector row CT. Multi-detector row CT-derived calcium scoring algorithms (ie, mineral mass and volume score) were compared with the mass and volume of ashed remnants of the CEA specimens. Bland-Altman analysis was performed to assess the mean (ie, bias) and SD (ie, precision) of differences between multi-detector row CT- and ashing-derived measurements. In addition, conventional Agatston score, volume score, mineral mass, and modified Agatston score were calculated for each specimen by using a number of scanning protocols. Images were obtained at a section thickness of 1.25 mm by using different tube energy settings and tube currents. Specimens were also imaged at different section thicknesses with fixed combinations of tube energy and tube current. To compare measurement variability of scoring methods, coefficients of variation for all protocols were calculated. RESULTS: Both mean multi-detector row CT-derived mineral mass and mean ashing-derived mineral mass were 0.129 g +/- 0.173 (r = 0.99, P <.001). Mean multi-detector row CT- and ashing-derived volumes were 339.94 mm3 +/- 395.4 and 39.48 mm3 +/- 55.76, respectively (r = 0.95, P <.001). Measurement bias relative to the reference ashing values was high (2,800.0%) for volume score and low (2.58%) for mineral mass. Measurement precision was 0.6% for volume score and greater than 0.0005% for mineral mass. Mean coefficients of variation for all CT protocols were 5.0% +/- 4.2 and 4.9% +/- 4.2 for mineral mass and modified Agatston score, respectively, and 16.0% +/- 9.2 and 14.5% +/- 3.9 for conventional Agatston and volume scores, respectively (P <.001). CONCLUSION: Compared with the conventional volume score, multi-detector row CT-derived mineral mass is a less biased and more precise measurement of the mineral content of nonmoving ex vivo CEA specimens. Mineral mass and modified Agatston score are more reproducible than conventional volume and Agatston scores.

Calcinosis↗

Isolated noncompaction of myocardium associated with calcification in the interventricular septum.

We describe a 12-year-old male with isolated noncompaction of the myocardium and associated abnormal calcification in the basal interventricular septum, and we present a review of the literature. The patient has been healthy and free of symptoms. The electrocardiogram showed abnormal Q waves in III, V1, V2, and ST elevation in V1-V3. Exercise testing demonstrated ST depression in V4 and V5. Myocardial scintigraphic examination showed a regional reduction in iodine-1,2,3-beta-methyl-iodophenylpentadecanoic acid uptake in the basal interventricular septum. Since coronary angiography demonstrated normal coronary vessels and the trabeculations were not prominent in this region, we hypothesize that coronary microcirculatory dysfunction may cause subendocardial infarction associated with calcification in the same area.

Calcinosis↗