PubMed Health⌕ Search

PubMed · 14511592

Detection of electron paramagnetic resonance absorption using frequency modulation.

Abstract

A frequency modulation (FM) method was developed to measure electron paramagnetic resonance (EPR) absorption. The first-derivative spectrum of 1,1-diphenyl-2-picrylhydrazyl (DPPH) powder was measured with this FM method. Frequency modulation of up to 1.6 MHz (peak-to-peak) was achieved at a microwave carrier frequency of 1.1 GHz. This corresponds to a magnetic field modulation of 57microT (peak-to-peak) at 40.3 mT. By using a tunable microwave resonator and automatic control systems, we achieved a practical continuous-wave (CW) EPR spectrometer that incorporates the FM method. In the present experiments, the EPR signal intensity was proportional to the magnitude of frequency modulation. The background signal at the modulation frequency (1 kHz) for EPR detection was also proportional to the magnitude of frequency modulation. An automatic matching control (AMC) system reduced the amplitude of noise in microwave detection and improved the baseline stability. Distortion of the spectral lineshape was seen when the spectrometer settings were not appropriate, e.g., with a lack of the open-loop gain in automatic tuning control (ATC). FM is an alternative to field modulation when the side-effect of field modulation is detrimental for EPR detection. The present spectroscopic technique based on the FM scheme is useful for measuring the first derivative with respect to the microwave frequency in investigations of electron-spin-related phenomena.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hiroshi Hirata, Toshifumi Kuyama, Mitsuhiro Ono, Yuhei Shimoyama. 2003. Detection of electron paramagnetic resonance absorption using frequency modulation.. https://doi.org/10.1016/s1090-7807(03)00236-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stereoselectivity by enantiomeric inhibitors of matrix metalloproteinase-8: new insights from molecular dynamics simulations.

Molecular Dynamics simulations in aqueous solution were performed for the matrix metalloproteinase-8 (MMP-8) free catalytic domain and for its complexes with the (R)- and (S)-[1-(4'-methoxybiphenyl-4-sulfonylamino)-2-methylpropyl] phosphonate. The 144-155 loop of the enzyme undergoes a drastic decrease of mobility once complexed with both enantiomers. The two enantiomers induce a different decrease of conformational entropy upon complexation. The higher affinity of the R-enantiomer can be related to the lower loss of conformational entropy accompanying its binding. The differences in the dynamical behavior of the protein induced by the two enantiomers are discussed at molecular level and the mode of binding of the simulated complexes is compared with that previously determined by X-ray crystallography.

Biphenyl Compounds↗

The unusual electrochemical and photophysical behavior of 2,2'-bis(1,3,4-oxadiazol-2-yl)biphenyls, effective electron transport hosts for phosphorescent organic light emitting diodes.

The fluorescence and phosphorescence of 2,2'-bis(5-phenyl-1,3,4-oxadiazol-2-yl)biphenyl shows good spectral matching with the absorption spectra of the MLCT1 and MLCT3 transitions of Ir(ppy)3. The red-shift of the 0-0 band in the phosphorescence at 77 K is due to the intramolecular pi-pi interactions between the oxadiazole side chains. Maximum brightness of 43,000 cd/m2 with an efficiency of 26 cd/A at 200 cd/m2 was achieved when BOBP was used as the host material for Ir(ppy)3 in the PHOLED study. [structure: see text].

Biphenyl Compounds↗

Rapid purification and scale-up of honokiol and magnolol using high-capacity high-speed counter-current chromatography.

In this paper, a rapid separation approach has been developed using high-capacity high-speed counter-current chromatography (high-capacity HSCCC) to isolate and purify honokiol and magnolol, which are the main bioactive constituents from Houpu. The optimization of the solvent selection process, sample loading volume and flow rate is systematically studied using analytical high-capacity HSCCC. The optimized parameters obtained rapidly at analytical scale were used for a 1000 x scale-up preparative run using pilot scale high-capacity HSCCC in a MAXI-DE centrifuge. A crude sample of 43 g was successfully separated and the fractions were analysed by high-performance liquid chromatography (HPLC). This large scale preparative single step run yielded 16.9 and 19.4 g of honokiol and magnolol with purities of 98.6 and 99.9%, in only 20 min. This is the first time that high-performance counter-current chromatography has been used to purify multiple gram grade bioactive compounds in less than 1h and at such high concentrations of final products (10.8 g/l for magnolol and 7.0 g/l for honokiol).

Biphenyl Compounds↗