PubMed Health⌕ Search

PubMed · 14531609

Adhesive permeability affects composite coupling to dentin treated with a self-etch adhesive.

Abstract

Dentin bonded with one-step self-etch adhesives does not couple well to chemically-cured composites despite the presence of ternary catalysts in some systems. To determine whether additional factors are responsible for the poor coupling of dentin bonded with these adhesives, the authors used a one-step self-adhesive in which the ternary catalyst is incorporated separately in the brush applicator for activating the adhesive. The activated adhesive was bonded to dentin or prepolymerized composites. For microtensile bond strength evaluation, a dual-cured hybrid composite was used for coupling to the bonded substrates and activated using: (1) the light-cured mode (LC), (2) delayed light-activation (DL) and (3) the chemical-cured mode (CC). In addition, the composite polymerized in the CC mode was coupled to the two substrates bonded with (4) additional experimental adhesive versions without the ternary catalyst and (5) without the ternary catalyst and tertiary amine. Silver tracer penetration into bonded interfaces was examined using TEM by replacing the dual-cured composite with a light-cured or a chemically-cured microfilled composite. In the CC mode, the composites coupled poorly to both substrates bonded with the unactivated adhesive (5). The use of activated adhesives allowed for good coupling of the composites polymerized in all curing modes to bonded composite, but only in the LC mode to bonded dentin. Water-filled channels in the form of water trees and water blisters were present in the adhesive layer under all composite-curing modes in bonded dentin. These features were completely absent in the bonded composites, showing that the source of the water was from dentin. Water blisters were also observed along the adhesive-composite interfaces in bonded dentin when the coupling composites were polymerized using the CC or DL modes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Franklin R Tay, David H Pashley, Mathilde C Peters. Adhesive permeability affects composite coupling to dentin treated with a self-etch adhesive.. https://pubmed.ncbi.nlm.nih.gov/14531609/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Healing substrates with mobile, particle-filled microcapsules: designing a 'repair and go' system.

We model the rolling motion of a fluid-driven, particle-filled microcapsule along a heterogeneous, adhesive substrate to determine how the release of the encapsulated nanoparticles can be harnessed to repair damage on the underlying surface. We integrate the lattice Boltzmann model for hydrodynamics and the lattice spring model for the micromechanics of elastic solids to capture the interactions between the elastic shell of the microcapsule and the surrounding fluids. A Brownian dynamics model is used to simulate the release of nanoparticles from the capsule and their diffusion into the surrounding solution. We focus on a substrate that contains a damaged region (e.g. a crack or eroded surface coating), which prevents the otherwise mobile capsule from rolling along the surface. We isolate conditions where nanoparticles released from the arrested capsule can repair the damage and thereby enable the capsules to again move along the substrate. Through these studies, we establish guidelines for designing particle-filled microcapsules that perform a 'repair and go' function and thus, can be utilized to repair damage in microchannels and microfluidic devices.

Adhesives↗

Bonding to ground versus unground enamel in fluorosed teeth.

OBJECTIVES: To determine the effect of grinding on the bonding effectiveness of a self-etch and an etch-and-rinse adhesive to fluorosed enamel. METHODS: The teeth were classified using the Thylstrup and Fejerskov index (TFI). Fluorosed teeth (TFI=5) obtained from Isparta (Turkey) and control teeth (TFI=0) obtained from Leuven (Belgium) were used. Using a depth-marking diamond bur, 0.3mm of enamel was removed from mid-buccal and mid-palatal/lingual surfaces of the teeth, whereas the area adjacent to the ground area was left unprepared. A two-step self-etch (Clearfil Protect Bond, Kuraray) and a three-step etch-and-rinse adhesive (Optibond FL, Kerr) were used to bond the resin composite to the ground and unground enamel. Rectangular micro-specimens were prepared using the slow-speed diamond saw and tested in tensile to determine the micro-tensile bond strength (microTBS). RESULTS: The microTBS to unground fluorosed enamel was significantly lower than to ground fluorosed enamel for Clearfil Protect Bond (15.8+/-15.2 and 45.0+/-12.4MPa, p<0.0001) and for Optibond FL (35.5+/-21.4 and 50.5+/-12.3MPa, p<0.05), respectively. In control teeth, Clearfil Protect Bond bonded better to ground enamel (p<0.01), whereas OptiBond FL exhibited a similar bonding effectiveness to ground and unground enamel (p=0.0634). SIGNIFICANCE: Preparation of enamel improved the resin-enamel bond strength in fluorosed teeth. The bonding effectiveness to unground enamel was lower in fluorosed teeth than in control teeth for the self-etch adhesive tested.

Adhesives↗