PubMed Health⌕ Search

PubMed · 14560789

Lipaemia: an overrated interference?

Abstract

Reagent method sheets for analysis of common serum analytes often highlight the possibility of interference from lipaemia but the information given is often brief and may not be instrument-specific. Thus study assesses the degree of interference from lipaemia in a range of common serum analytes on the Bayer Opera (with a serum blank) using a commercial polymer, LipoClear, as a lipid-clearing agent. Serum samples (mean serum triglyceride 6.89 [range 0.58-28.4] mmol/L) are analysed for 14 common chemistry analytes and the results compared before and after treatment with LipoClear. Results showed no significant critical differences in analyte values before and after treatment, except for an expected fall in total protein, phosphate, cholesterol and triglyceride concentrations. Most of the common analytes in use on the Bayer Opera are not subject to interference from lipaemia; however, we recommend that where method sheets indicate interference from lipaemia then this should be quantified for the analyte in question.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N R Anderson, S Slim, R Gama, M R Holland. 2003. Lipaemia: an overrated interference?. https://doi.org/10.1080/09674845.2003.11783690

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗