Pneumothorax during laparoscopy.

Abstract

BACKGROUND: Pneumothorax is a known complication of laparoscopy, with most pneumothoraces diagnosed postoperatively with conventional chest x-ray. Electrocardiogram (ECG) conduction changes are associated with pneumothorax. In a sheep model, ECG changes were evaluated as a potential indicator of intraoperative pneumothorax. Additionally, resolution rates of helium (He) and carbon dioxide (CO2) pneumothorax were also evaluated in this model. METHODS: Under general anesthesia, 10 sheep had known volumes (20-100 cc) of either He or CO2 introduced into the left hemithorax. A 12-lead ECG recorded changes associated with the induced pneumothorax. After changes in the ECG plateaued, the gas volume in the hemithorax was increased to 2 L and the resultant pneumothorax was followed for a 2-h period using fluoroscopy to determine resolution rates for the different gas pneumothoraces. Gas volumes were aspirated after 2 h and ECGs were again recorded. RESULTS: Pneumothorax volumes as low as 20 cc produced consistent ECG changes. The amplitude of the precordial QRS complex was seen to diminish, and this lowering of the QRS amplitude continued as pneumothorax volume increased up to 100 cc. The ECG returned to prepneumothorax patterns with aspiration of the left chest. For different gas pneumothoraces, CO(2) pneumothorax showed almost complete resolution in the 2-h period, whereas He pneumothorax was unchanged. CONCLUSIONS: Precordial ECG changes appear to be a very sensitive indicator of pneumothorax, with very small pneumothorax (<100 cc) consistently being detected by reduction of the QRS complex amplitude. Intraoperative use of precordial ECG leads could result in rapid identification of pneumothorax during laparoscopic surgery. Carbon dioxide pneumothorax shows near 100% resolution in a 2-h period. This supports recommendations of expectant management in asymptomatic patients with CO(2) pneumothorax. However, He pneumothorax does not resolve spontaneously quickly and may require aspiration even in asymptomatic patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Ludemann, R Krysztopik, G G Jamieson, D I Watson. 2003-10-23. Pneumothorax during laparoscopy.. https://doi.org/10.1007/s00464-003-8126-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Preparation of a biodegradable matrix through polyion complex formation by mixing polylactide-based microspheres having oppositely charged surfaces.

The aggregation of polyions into microsphere (MS) complexes was studied as a preparative method for the construction of a biodegradable matrix. Aqueous suspensions of polylactide (PLA)-based MSs with positively and negatively charged surfaces, MS(K(3)(4+)-PLA) and MS(E(3)(4-)-PLA), respectively, immediately formed aggregates when mixed. The effects of the stoichiometry of the charged groups on the surfaces of the MSs and the ionic strength of the medium on aggregate formation, as well as the degradation behavior of the polyion complex (PIC) matrix over time, were investigated.

Absorption↗

Needle concentrator for gas chromatographic determination of BTEX in aqueous samples.

A simple method of solventless extraction of volatile organic compounds (BTEX) from aqueous samples was developed and validated. A new arrangement of the full volume inside needle capillary adsorption trap (INCAT) device with Porapak Q as a sorbent material and wet alumina as a source of desorptive water vapour flow in a closed analytical system is presented. The analytical characteristics of developed device and of compared purge-and-trap (PTI) device for BTEX compounds are similar; the limits of detection as well as quantification are lower than 1 microg l(-1).

Absorption↗

A microdialysis model to examine nasal drug delivery and olfactory absorption in rats using lidocaine hydrochloride as a model drug.

Targeting of the central nervous system by direct drug transport from the nose to the brain has gained increased attention through the last decade. In the present study, a model for olfactory drug absorption has been investigated using intravenous and unilateral nasal administration of lidocaine hydrochloride in rats. To investigate the possible drug delivery aspects of this route of transport to a central part of the brain a microdialysis model using in vivo recovery by calibrator was applied to the systemic blood and to right and left striatum. The integrity of the blood-brain barrier was evaluated following microdialysis probe implantation. The in vivo experiments were carried out as a cross-over study in rats. The drainage from the nasal cavity was not restricted by occlusion. It was found that true unbound lidocaine concentrations could be calculated from in vivo recovery measurements of retrodialysis of prilocaine hydrochloride. The relative in vivo recoveries in striatum (11.3%) and blood (24.0%) were significantly lower than in vitro (31.3 and 44.9%). The blood-brain barrier was found to retain its physical integrity when evaluated one hour after probe implantation. From pharmacokinetic modelling of the time-concentration curves it was found that the absorption rates and area under the curve (AUC) values of lidocaine in left and right striatum were not statistically different following nasal and intravenous administration, respectively. The average nasal bioavailabilities of lidocaine in blood, left and right striatum were 85, 103 and 129%, respectively. It was concluded that no significant olfactory absorption to striatum was evident in the present study. However, the method should be applicable to studies of drug delivery to blood and brain following nasal administration of other drugs.

Absorption↗