PubMed Health⌕ Search

PubMed · 14580912

Biodegradable poly(ether ester urethane)urea elastomers based on poly(ether ester) triblock copolymers and putrescine: synthesis, characterization and cytocompatibility.

Abstract

Polymers with elastomeric mechanical properties, tunable biodegradation properties and cytocompatibility would be desirable for numerous biomedical applications. Toward this end a series of biodegradable poly(ether ester urethane)urea elastomers (PEEUUs) based on poly(ether ester) triblock copolymers were synthesized and characterized. Poly(ether ester) triblock copolymers were synthesized by ring-opening polymerization of epsilon-caprolactone with polyethylene glycol (PEG). PEEUUs were synthesized from these triblock copolymers and butyl diisocyanate, with putrescine as a chain extender. PEEUUs exhibited low glass transition temperatures and possessed tensile strengths ranging from 8 to 20MPa and breaking strains from 325% to 560%. Increasing PEG length or decreasing poly(caprolactone) length in the triblock segment increased PEEUU water absorption and biodegradation rate. Human umbilical vein endothelial cells cultured in a medium supplemented with PEEUU biodegradation solution suggested a lack of degradation product cytotoxicity. Endothelial cell adhesion to PEEUUs was less than 60% of tissue culture polystyrene and was inversely related to PEEUU hydrophilicity. Surface modification of PEEUUs with ammonia gas radio-frequency glow discharge and subsequent immobilization of the cell adhesion peptide Arg-Gly-Asp-Ser increased endothelial adhesion to a level equivalent to tissue culture polystyrene. These biodegradable PEEUUs thus possessed properties that would be amenable to applications where high strength and flexibility would be desirable and exhibited the potential for tuning with appropriate triblock segment selection and surface modification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jianjun Guan, Michael S Sacks, Eric J Beckman, William R Wagner. 2004. Biodegradable poly(ether ester urethane)urea elastomers based on poly(ether ester) triblock copolymers and putrescine: synthesis, characterization and cytocompatibility.. https://doi.org/10.1016/s0142-9612(03)00476-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simplified MRI sequences for postoperative control of hamstring anterior cruciate ligament reconstruction.

INTRODUCTION: Usually, standard radiographs are used for postoperative quality follow-up after ACL reconstruction. However, with the use of hamstring grafts and bioabsorbable implants, accurate assessment of the tunnel and implant position is impossible. The graft and its relation to anatomical landmarks cannot be evaluated directly. MRI is an alternative to radiography, permitting direct graft visualization and 3-dimensional assessment of the tunnel position, but it is expensive and time consuming for routine use. The aim of this study was to develop a simplified MRI protocol and to evaluate it for routine postoperative quality follow-up after ACL reconstruction. MATERIALS AND METHODS: Various scanning protocols were tested in a series of 105 patients and evaluated for image sharpness, clarity of the structures, susceptibility to artefacts, applicability regarding precise analysis of graft and tunnel position, and time consumption. One simplified specific scan protocol was then defined and applied in a series of 60 consecutive patients after hamstring ACL replacement. The position of the femoral and tibial tunnels was measured in the sagittal, coronal and axial sections and classified according to Harner (femoral) and Stäubli (tibial). Impingement of the graft in the intercondylar roof was analysed according to Howell. The position of the bioabsorbable interference screws was assessed. RESULTS: Scan protocol: T2-weighted gradient-echo sequences (GRE) with TR 246 ms, TE 11 ms, flip angle 25 degrees, 2 mm sections and a 256 x 256 matrix yielded the best image quality of tendon grafts and bone tunnels with tolerable time consumption (average scanning time per patient 1 min 40 s). Altogether 8-16 sections were obtained for every patient. Tunnel placement: 46/60 (77%) of the femoral tunnels were in zone 4, 13/60 (21%) at the border of zones 3 to 4, 1/60 (2%) in zone 3 in the sagittal plane (Harner). The femoral tunnels in the axial plane were at 10:30 o'clock in 32/60 (53%), at 11:00 o'clock at 24/60 (40%) and at 10:00 o'clock in 4/60 (4%) patients. The mean distance of the anterior border of the tibial tunnel from the anterior cortex was 39% (+/- 4.9%) related to the total sagittal diameter of the tibia. There was no graft impingement. The position of the interference screws was anterior to the grafts in all cases. CONCLUSION: Simplified MRI sequences can be used for postoperative quality follow-up after ACL replacement and are an alternative to standard radiographs giving more specific and precise information regarding tunnel position and screw placement. Analyzing the bone tunnels in a series of 60 patients demonstrated that correct assessment of tunnel placement after arthroscopic ACL reconstruction is feasible using this simplified MRI technique.

Absorbable Implants↗

In vitro and in vivo correlation of buserelin release from biodegradable implants using statistical moment analysis.

Here we investigated the possibility to develop different levels of correlation between in vitro drug release profiles and in vivo pharmacokinetic parameters for three Buserelin implant formulations. The in vitro and in vivo data were analyzed using model-independent and model-dependent methods. Since diffusion, dissolution and erosion effects influence drug release in most cases a simple kinetic model is unlikely to explain the overall in vivo release behavior. Thus the in vitro drug release curves were analyzed according to the theoretical models of Higuchi and Korsmeyer-Peppas. For the formulation with predominant diffusion controlled release level A IVIVC could be established (R2=0.986). Independent on drug release mechanism, a level B correlation between the mean in vitro dissolution time (MDT) and mean in vivo residence time (MRT) was obtained with a correlation coefficient of 0.983. Finally, level C correlation were observed when single in vitro parameters, e.g. T50% (time required to release 50% of drug in vitro) where compared with single in vivo parameters like AUC. This study suggests that a level B correlation could be achieved even when drug release occurs by a combination of diffusion and erosion processes. More sophisticated in vitro models mimicking drug release under in vivo conditions are clearly desirable for parenteral depot formulations.

Absorbable Implants↗

Hamstring anterior cruciate ligament reconstruction: a comparison of bioabsorbable interference screw and endobutton-post fixation.

PURPOSE: The purpose of this study was to evaluate hamstring anterior cruciate ligament (ACL) reconstruction using aperture fixation with bioabsorbable interference screw (BIS) and distant fixation using EndoButton (Smith & Nephew, Andover, MA) and screw-post (ENDO). TYPE OF STUDY: Prospective nonrandomized clinical outcome study. METHODS: Two groups of 15 patients who underwent autogenous hamstring ACL reconstruction with a minimum of 2 years' follow-up evaluation (mean 35 months) were included in the study. The BIS group underwent poly-L-lactic acid interference screw fixation at both femoral and tibial tunnels and the ENDO group underwent EndoButton fixation on the femoral side and screw-post fixation on the tibial side. Clinical evaluation included International Knee Documentation Committee (IKDC) and arthrometer measurements. Tunnel enlargement, screw integrity, graft integrity, and graft-tunnel interface were evaluated using radiographs and magnetic resonance imaging. Statistical analyses were performed using the Student t test, with significance set at 0.05. RESULTS: All patients in both groups had functionally normal or near-normal IKDC scores. The average IKDC subjective knee form scores were 85 +/- 11 versus 81 +/- 17 (BIS v ENDO) and side-to-side KT differences were 3.2 +/- 2.6 mm versus 2.4 +/- 1.8 mm (P >.05). For both groups, tunnel enlargement was present on radiographs at both femoral and tibial sides (36% to 77%). Tunnel enlargement was more significant at the femoral tunnels (53% to 77%) than the tibial tunnels (36% to 42%). In the BIS group, magnetic resonance imaging revealed 9 partially degraded screws and 2 intact screws on the femoral side. On the tibial side, 4 partially degraded and 10 intact screws were seen. For both groups, the grafts have partial or complete incorporation at all tunnels. Tunnel enlargement measured on radiographs correlate well with measurements on magnetic resonance images. CONCLUSIONS: Our results showed that rigid aperture fixation using BIS did not lead to significant differences in clinical outcome when compared with distant fixation using ENDO at 24 to 40 months follow-up evaluation. Significant tunnel enlargement was present in both groups, more pronounced on the femoral side. Magnetic resonance imaging findings showed that BIS were not degraded even at 2 to 4 years after surgery. LEVEL OF EVIDENCE: Level II.

Absorbable Implants↗