PubMed Health⌕ Search

PubMed · 14658770

The chromatic input to global motion perception.

Abstract

For over 30 years there has been a controversy over whether color-defined motion can be perceived by the human visual system. Some results suggest that there is no chromatic motion mechanism at all, whereas others do find evidence for a purely chromatic motion mechanism. Here we examine the chromatic input to global motion processing for a range of color directions in the photopic luminance range. We measure contrast thresholds for global motion identification and simple detection using sparse random-dot kinematograms. The results show a discrepancy between the two chromatic axes: whereas it is possible for observers to perform the global motion task for stimuli modulated along the red-green axis, we could not assess the contrast threshold required for stimuli modulated along the yellowish-violet axis. The contrast required for detection for both axes, however, are well below the contrasts required for global motion identification. We conclude that there is a significant red-green input to global motion processing providing further evidence for the involvement of the parvocellular pathway. The lack of S-cone input to global motion processing suggests that the koniocellular pathway mediates the detection but not the processing of complex motion for our parameter range.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alexa I Ruppertsberg, Sophie M Wuerger, Marco Bertamini. The chromatic input to global motion perception.. https://doi.org/10.1017/s0952523803204077

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗