PubMed Health⌕ Search

PubMed · 14668754

Finite element analysis to determine implant preload.

Abstract

STATEMENT OF PROBLEM: The nature of the forces used to clamp implant components together, and how they are generated and sustained, is lacking in the literature. PURPOSE: This study examined the dynamic nature of developing the preload in an implant complex using finite element analysis. METHODS: The implant complex was modeled in accordance with the geometric designs for the Nobel Biocare implant systems. A thread helix design for the abutment screw and implant screw bore was modeled to create the geometric design for these units of the implant systems. Using the software programs HyperWorks and LS3D-Dyna, 2 3-dimensional finite element models of (1) a Branemark System 3.75 x 10-mm titanium Mark III implant, a CeraOne titanium abutment, a Unigrip gold alloy abutment screw, and (2) a Replace Select System 4.30 x 10-mm titanium implant, a Straight Esthetic titanium abutment, and a TorqTite titanium abutment screw were created. Modeling the threads to the machining specifications permitted simulation of screw tightening. The abutment screws were subjected to a tightening torque in increments of 1 Ncm from 0 to 64 Ncm using ABAQUS software. Using these models, the effect of the coefficient of friction on the development of preload amount in the implant complex during and after abutment screw tightening was determined. In the first experiment, the coefficient of friction was set to 0.20 between the titanium bearing surface of the abutments and the implant bearing surfaces, and 0.26 between the gold abutment screw and the titanium implant screw bore. In the second experiment, the coefficient of friction was varied; the titanium implant and titanium abutment bearing surfaces were set to a coefficient of friction of 0.20, whereas the Mark III gold and the Replace Select titanium abutment screws and their respective titanium screw bores in the implants were set to 0.12. The preload amount (N) was determined from the finite element analysis. RESULTS: The stress distribution pattern clearly demonstrated a transfer of preload force from the screw to the implant during tightening. A preload of 75% of the yield strength of the abutment screw was not established using the recommended tightening torques. CONCLUSION: Using finite element analysis, a torque of 32 Ncm applied to the abutment screws in the implant assemblies studied in the presence of a coefficient of friction of 0.26 resulted in a lower than optimum preload for the abutment screws. To reach the desired preload of 75% of the yield strength, using a torque of 32 Ncm applied to the abutment screws in the implant assemblies studied, the coefficient of friction between the implant components should be 0.12.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lisa A Lang, Byungsik Kang, Rui-Feng Wang, Brien R Lang. 2003. Finite element analysis to determine implant preload.. https://doi.org/10.1016/j.prosdent.2003.09.012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of attachment wear on retention of mandibular overdenture.

UNLABELLED: The aims of this study were: (i) to evaluate and compare retention of two-teeth (implant) supported mandibular overdenture with either stud or magnetic attachments during linear (axial) and rotational (paraxial) dislodgements; (ii) to compare retentive properties before and after wear simulation. The test group consisted of five magnetic and four stud overdenture attachments (n = 12 specimens for each attachment type). Retention in axial direction was evaluated on one-tooth (implant) model by measuring maximum retentive force (N) and range of retention (mm) during the linear dislodgement. Retention in the paraxial direction was evaluated on mandibular-overdenture model by measuring the maximum retentive force (N) during three types of rotational dislodgements - anterior, lateral and posterior. The minimum number of cycles required to simulate wear was determined by special wear test. Afterwards, the wear was simulated in the test group, and retention in axial and paraxial directions was measured again. STATISTICAL ANALYSIS: one-way anova, Scheffe post hoc and paired-samples t-tests (P < 0.05). Initially, studs had higher retention (4-11 N) than magnets (4.5-6 N) in axial direction. After the wear simulation, it had decreased from 76% to 48% for some of the studs and had become similar to the retention of magnetic attachments. Magnets had lower retention range (0.2-0.3 mm) than studs (0.5-1.1 mm). Studs provided similar or higher retention in paraxial directions than magnetic attachments both before and after wear simulation. Retentive properties of magnets decreased mostly with posterior rotational dislodgement. Retentive properties of stud overdenture attachments were less constant.

Dental Abutments↗

Transitioning patients from teeth to implants.

One major obstacle to treatment with implants is the transitional phase between a tooth supported occlusion and an implant supported occlusion. This is of particular concern when a patient with a failing dentition has not worn a removable prosthesis before and is planning to have a reconstruction supported by implants.

Dental Abutments↗

Impression techniques for implant dentistry.

The object of making an impression in implant dentistry is to accurately relate an analogue of the implant or implant abutment to the other structures in the dental arch. This is affected by use of an impression coping which is attached to the implant or implant abutment. This impression coping is incorporated in an impression - much as a metal framework is 'picked up' in a remount impression for fixed prosthodontics. With implant copings the coping is usually attached to the implant or abutment with screws. The impression material used is usually an elastomeric impression material; the two types most widely used and shown to be the most appropriate are polyether and polyvinyl siloxane impression materials.

Dental Abutments↗